Your browser doesn't support javascript.
loading
Movement measurements at home for multiple sclerosis: walking speed measured by a novel ambient measurement system.
Smith, Victoria Mj; Varsanik, Jonathan S; Walker, Rachel A; Russo, Andrew W; Patel, Kevin R; Gabel, Wendy; Phillips, Glenn A; Kimmel, Zebadiah M; Klawiter, Eric C.
Afiliação
  • Smith VM; Massachusetts General Hospital, Harvard Medical School, USA.
  • Varsanik JS; Atlas5D, Inc., USA.
  • Walker RA; Atlas5D, Inc., USA.
  • Russo AW; Massachusetts General Hospital, Harvard Medical School, USA.
  • Patel KR; Massachusetts General Hospital, Harvard Medical School, USA.
  • Gabel W; Value-based Medicine Group, Biogen, USA.
  • Phillips GA; Value-based Medicine Group, Biogen, USA.
  • Kimmel ZM; Atlas5D, Inc., USA.
  • Klawiter EC; Massachusetts General Hospital, Harvard Medical School, USA.
Mult Scler J Exp Transl Clin ; 4(1): 2055217317753465, 2018.
Article em En | MEDLINE | ID: mdl-29383266
BACKGROUND: Gait disturbance is a major contributor to clinical disability in multiple sclerosis (MS). A sensor was developed to assess walking speed at home for people with MS using infrared technology in real-time without the use of wearables. OBJECTIVE: To develop continuous in-home outcome measures to assess gait in adults with MS. METHODS: Movement measurements were collected continuously for 8 months from six people with MS. Average walking speed and peak walking speed were calculated from movement data, then analyzed for variability over time, by room (location), and over the course of the day. In-home continuous gait outcomes and variability were correlated with standard in-clinic gait outcomes. RESULTS: Measured in-home average walking speed of participants ranged from 0.33 m/s to 0.96 m/s and peak walking speed ranged from 0.89 m/s to 1.51 m/s. Mean total within-participant coefficient of variation for daily average walking speed and peak walking speed were 10.75% and 10.93%, respectively. Average walking speed demonstrated a moderately strong correlation with baseline Timed 25-Foot Walk (rs = 0.714, P = 0.111). CONCLUSION: New non-wearable technology provides reliable and continuous in-home assessment of walking speed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mult Scler J Exp Transl Clin Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mult Scler J Exp Transl Clin Ano de publicação: 2018 Tipo de documento: Article