Your browser doesn't support javascript.
loading
Variability induced by the MR imager in dynamic contrast-enhanced imaging of the prostate.
Brunelle, S; Zemmour, C; Bratan, F; Mège-Lechevallier, F; Ruffion, A; Colombel, M; Crouzet, S; Sarran, A; Rouvière, O.
Afiliação
  • Brunelle S; Department of imaging, institut Paoli-Calmettes, 13273 Marseille, France.
  • Zemmour C; Inserm, department of clinical research and investigation, biostatistics and methodology unit, institut Paoli-Calmettes, IRD, SESSTIM, Aix Marseille université, 13273 Marseille, France.
  • Bratan F; Hospices civils de Lyon, department of urinary and vascular radiology, hôpital Édouard-Herriot, 69437 Lyon, France.
  • Mège-Lechevallier F; Hospices civils de Lyon, department of pathology, hôpital Édouard-Herriot, 69437 Lyon, France.
  • Ruffion A; Hospices civils de Lyon, department of urology, centre hospitalier Lyon Sud, 69310 Pierre-Bénite, France.
  • Colombel M; Hospices civils de Lyon, department of urology, hôpital Édouard-Herriot, 69437 Lyon, France; Université de Lyon, 69003 Lyon, France; Faculté de médecine Lyon Est, université Lyon 1, 69003 Lyon, France.
  • Crouzet S; Hospices civils de Lyon, department of urology, hôpital Édouard-Herriot, 69437 Lyon, France; Université de Lyon, 69003 Lyon, France; Faculté de médecine Lyon Est, université Lyon 1, 69003 Lyon, France.
  • Sarran A; Department of imaging, institut Paoli-Calmettes, 13273 Marseille, France.
  • Rouvière O; Hospices civils de Lyon, department of urinary and vascular radiology, hôpital Édouard-Herriot, 69437 Lyon, France; Université de Lyon, 69003 Lyon, France; Faculté de médecine Lyon Est, université Lyon 1, 69003 Lyon, France. Electronic address: Olivier.rouviere@netcourrier.com.
Diagn Interv Imaging ; 99(4): 255-264, 2018 Apr.
Article em En | MEDLINE | ID: mdl-29428316
PURPOSE: To evaluate the variability induced by the imager in discriminating high-grade (Gleason≥7) prostate cancers (HGC) using dynamic contrast-enhanced MRI. MATERIAL AND METHODS: We retrospectively selected 3T MRIs with temporal resolution<10 seconds and comprising T1 mapping from a prospective radiologic-pathologic database of patients treated by prostatectomy. Ktrans, Kep, Ve and Vp were calculated for each lesion seen on MRI using the Weinmann arterial input function (AIF) and three patient-specific AIFs measured in the right and left iliac arteries in pixels in the center of the lumen (psAIF-ST) or manually selected by two independent readers (psAIF-R1 and psAIF-R2). RESULTS: A total of 43 patients (mean age, 63.6±4.9 [SD]; range: 48-72 years) with 100 lesions on MRI (55 HGC) were selected. MRIs were performed on imager A (22 patients, 49 lesions) or B (21 patients, 51 lesions) from two different manufacturers. Using the Weinmann AIF, Kep (P=0.005), Ve (P=0.04) and Vp (P=0.01) significantly discriminated HCG. After adjusting on tissue classes, the imager significantly influenced the values of Kep (P=0.049) and Ve (P=0.007). Using patient-specific AIFs, Vp with psAIF-ST (P=0.008) and psAIF-R2 (P=0.04), and Kep with psAIF-R1 (P=0.03) significantly discriminated HGC. After adjusting on tissue classes, types of patient-specific AIF and side of measurement, the imager significantly influenced the values of Ktrans (P=0.0002), Ve (P=0.0072) and Vp (P=0.0003). For all AIFs, the diagnostic value of pharmacokinetic parameters remained unchanged after adjustment on the imager, with stable odds ratios. CONCLUSION: The imager induced variability in the absolute values of pharmacokinetic parameters but did not change their diagnostic performance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Imageamento por Ressonância Magnética / Meios de Contraste Tipo de estudo: Observational_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Imaging Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Imageamento por Ressonância Magnética / Meios de Contraste Tipo de estudo: Observational_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Imaging Ano de publicação: 2018 Tipo de documento: Article