Your browser doesn't support javascript.
loading
Fatigue resistance, electrochemical corrosion and biological response of Ti-15Mo with surface modified by amorphous TiO2 nanotubes layer.
Campanelli, Leonardo C; Oliveira, Nilson T C; da Silva, Paulo Sergio C P; Bolfarini, Claudemiro; Palmieri, Annalisa; Cura, Francesca; Carinci, Francesco; Motheo, Artur J.
Afiliação
  • Campanelli LC; Federal University of São Carlos, Department of Materials Engineering, São Carlos, SP, Brazil.
  • Oliveira NTC; University of São Paulo, São Carlos Institute of Chemistry, São Carlos, SP, Brazil.
  • da Silva PSCP; Federal University of São Carlos, Department of Materials Engineering, São Carlos, SP, Brazil.
  • Bolfarini C; Federal University of São Carlos, Department of Materials Engineering, São Carlos, SP, Brazil.
  • Palmieri A; University of Bologna, Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy.
  • Cura F; University of Bologna, Department of Experimental, Diagnostic and Specialty Medicine, Bologna, Italy.
  • Carinci F; University of Ferrara, Department of Morphology, Surgery and Experimental Medicine, Ferrara, Italy.
  • Motheo AJ; University of São Paulo, São Carlos Institute of Chemistry, São Carlos, SP, Brazil.
J Biomed Mater Res B Appl Biomater ; 107(1): 86-96, 2019 01.
Article em En | MEDLINE | ID: mdl-29504241
The objective of this work was a systemic evaluation of the anodizing treatment in a ß-type Ti-15Mo alloy to grow a TiO2 nanostructured layer for osseointegration improvement. The technical viability of the surface modification was assessed based on the resistance to mechanical fatigue, electrochemical corrosion, and biological response. By using an organic solution of NH4 F in ethylene glycol, a well-organized array of 90 nm diameter nanotubes was obtained with a potential of 40 V for 6 h, while undefined nanotubes of 25 nm diameter were formed with a potential of 20 V for 1 h. Nevertheless, the production of the 90 nm diameter nanotubes was followed by micrometer pits that significantly reduced the fatigue performance. The undefined nanotubes of 25 nm diameter, besides the greater cell viability and improved osteoblastic cell differentiation in comparison to the as-polished surface, were not deleterious to the fatigue and corrosion properties. This result strengthens the necessity of an overall evaluation of the anodizing treatment, particularly the fatigue resistance, before suggesting it for the design of implants. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 107B: 86-96, 2019.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoblastos / Titânio / Teste de Materiais / Materiais Revestidos Biocompatíveis / Nanotubos / Ligas / Técnicas Eletroquímicas Limite: Humans Idioma: En Revista: J Biomed Mater Res B Appl Biomater Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoblastos / Titânio / Teste de Materiais / Materiais Revestidos Biocompatíveis / Nanotubos / Ligas / Técnicas Eletroquímicas Limite: Humans Idioma: En Revista: J Biomed Mater Res B Appl Biomater Ano de publicação: 2019 Tipo de documento: Article