Immediate and flapless implant insertion and provisionalization using autogenous bone grafts in the esthetic zone: 5-year results.
Noelken, Robert; Moergel, Maximilian; Kunkel, Martin; Wagner, Wilfried.
Afiliação
  • Noelken R; Private Practice for Oral Surgery, Lindau/Lake Constance, Germany.
  • Moergel M; Department of Oral and Maxillofacial Surgery - Plastic Surgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
  • Kunkel M; Department of Oral and Maxillofacial Surgery - Plastic Surgery, University Medical Center, Johannes Gutenberg University of Mainz, Mainz, Germany.
  • Wagner W; Department of Oral and Maxillofacial Surgery, University Hospital of Bochum, Bochum, Germany.
Clin Oral Implants Res ; 29(3): 320-327, 2018 Mar.
Article em En | MEDLINE | ID: mdl-29537706
OBJECTIVES: As the 2-year results for immediately inserted and provisionalized implants have been reported, it remained an open issue, whether the initially high success rates and the esthetic outcome remain stable for longer observation periods. Therefore, this prospective study examines the 5-year hard and soft tissue changes at implants placed in the anterior maxilla. MATERIAL AND METHODS: Meanwhile, 37 microthreaded implants were placed in 21 patients into extraction sockets with and without facial bone deficiencies by a flapless approach. Facial gaps and bony defects were grafted with autogenous bone chips. The implants were immediately provisionalized. The primary outcome parameters were the interproximal marginal bone level and the thickness of the facial bony wall. Implant success and Pink Esthetic Score (PES) were considered as secondary outcome parameters. RESULTS: Two patients with four implants withdrew from the study (dropouts), and the remaining 33 implants were still in function at a follow-up period of 68 months. Marginal bone height averaged 0.04 mm coronal to the implant shoulder. The thickness of the facial bony lamellae increased significantly between pre-op examination and 1-year follow-up (p = .002) and thereafter remained stable. Within 5 years of follow-up, 24 of 33 implants were clinically stable, free of signs and symptoms, and showed bone loss less than 1 mm. The mean PES ratings improved slightly from 10.7 pre-operatively to 11.7 at the last follow-up (p = .02). CONCLUSIONS: Interproximal marginal bone levels, survival rates, and esthetic results remain stable at the 5-year follow-up in implants used in an immediate insertion, reconstruction, and provisionalization concept. Facial marginal bone levels decreased slightly; however, this reduction did not affect the PES so far.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Perda do Osso Alveolar / Transplante Ósseo / Alvéolo Dental / Estética Dentária / Carga Imediata em Implante Dentário / Maxila Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Clin Oral Implants Res Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Perda do Osso Alveolar / Transplante Ósseo / Alvéolo Dental / Estética Dentária / Carga Imediata em Implante Dentário / Maxila Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Clin Oral Implants Res Ano de publicação: 2018 Tipo de documento: Article