Automatic interstitial photodynamic therapy planning via convex optimization.
Yassine, Abdul-Amir; Kingsford, William; Xu, Yiwen; Cassidy, Jeffrey; Lilge, Lothar; Betz, Vaughn.
Afiliação
  • Yassine AA; Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, 10 King's College Rd, Toronto, ON M5S3G8, Canada.
  • Kingsford W; abed.yassine@mail.utoronto.ca.
  • Xu Y; Division of Engineering Science, University of Toronto, 27 King's College Circle, Toronto, ON M5S1A1, Canada.
  • Cassidy J; william.kingsford@mail.utoronto.ca.
  • Lilge L; Department of Mathematics, University of British Columbia, 1980 Mathematics Road, Vancouver, BC V6T1Z2, Canada.
  • Betz V; Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, 10 King's College Rd, Toronto, ON M5S3G8, Canada.
Biomed Opt Express ; 9(2): 898-920, 2018 Feb 01.
Article em En | MEDLINE | ID: mdl-29552420
ABSTRACT
Finding a high-quality treatment plan is an essential, yet difficult, stage of Photodynamic therapy (PDT) as it will determine the therapeutic efficacy in eradicating malignant tumors. A high-quality plan is patient-specific, and provides clinicians with the number of fiber-based spherical diffusers, their powers, and their interstitial locations to deliver the required light dose to destroy the tumor while minimizing the damage to surrounding healthy tissues. In this work, we propose a general convex light source power allocation algorithm that, given light source locations, guarantees optimality of the resulting solution in minimizing the over/under-dosage of volumes of interest. Furthermore, we provide an efficient framework for source selection with concomitant power reallocation to achieve treatment plans with a clinically feasible number of sources and comparable quality. We demonstrate our algorithms on virtual test cases that model glioblastoma multiforme tumors, and evaluate the performance of four different photosensitizers with different activation wavelengths and specific tissue uptake ratios. Results show an average reduction of the damage to organs-at-risk (OAR) by 29% to 31% with comparable runtime to existing power allocation techniques.