Your browser doesn't support javascript.
loading
An Update on the Adjunctive Neurovascular Support of Wide-Neck Aneurysm Embolization and Reconstruction Trial: 1-Year Safety and Angiographic Results.
Spiotta, A M; Chaudry, M I; Turner, R D; Turk, A S; Derdeyn, C P; Mocco, J; Tateshima, S.
Afiliação
  • Spiotta AM; From the Department of Neurosurgery (A.M.S., M.I.C., R.D.T., A.S.T.), Medical University of South Carolina, Charleston, South Carolina spiotta@musc.edu.
  • Chaudry MI; From the Department of Neurosurgery (A.M.S., M.I.C., R.D.T., A.S.T.), Medical University of South Carolina, Charleston, South Carolina.
  • Turner RD; From the Department of Neurosurgery (A.M.S., M.I.C., R.D.T., A.S.T.), Medical University of South Carolina, Charleston, South Carolina.
  • Turk AS; From the Department of Neurosurgery (A.M.S., M.I.C., R.D.T., A.S.T.), Medical University of South Carolina, Charleston, South Carolina.
  • Derdeyn CP; Department of Radiology (C.P.D.), University of Iowa, Iowa City, Iowa.
  • Mocco J; Department of Neurosurgery (J.M.), Mount Sinai Hospital, New York, New York.
  • Tateshima S; Department of Radiology (S.T.), University of California, Los Angeles, Los Angeles, California.
AJNR Am J Neuroradiol ; 39(5): 848-851, 2018 05.
Article em En | MEDLINE | ID: mdl-29599174
ABSTRACT
BACKGROUND AND

PURPOSE:

The safety and efficacy of the PulseRider for the treatment of wide-neck, bifurcation aneurysms at the basilar and carotid terminus locations were studied in a prospective trial, the Adjunctive Neurovascular Support of Wide-Neck Aneurysm Embolization and Reconstruction (ANSWER) trial, reporting on initial 6-month angiographic and clinical results. This report provides insight into the longer term durability and safety with 12-month data. MATERIALS AND

METHODS:

Aneurysms treated with the PulseRider among enrolled sites were prospectively studied. Updated 12-month data on clinical and imaging end points are included.

RESULTS:

Thirty-four patients were enrolled (29 women, 5 men) with a mean age of 60.9 years. The mean aneurysm height ranged from 2.4 to 15.9 mm with a mean neck size of 5.2 mm (range, 2.3-11.6 mm). At 1 year, there were no device migrations or symptomatic in-stent stenoses. Raymond-Roy I occlusion was achieved in 53% of cases at the time of treatment and progressed to 61% and 67% at 6 and 12 months, respectively. Adequate occlusion (Raymond-Roy I/II) progressed from 88% at 6 months to 90% at 12 months. No recanalizations were observed. There was 1 delayed ischemic event. Good outcome (mRS 0-2) was achieved in 90% of patients.

CONCLUSIONS:

The updated 1-year results from the ANSWER trial demonstrate aneurysm stability and an acceptable safety profile for aneurysms treated at the basilar apex and carotid terminus. Prospective data from a larger set of aneurysms treated at other locations are required to assess how treatment with PulseRider compares with alternatives for treating wide-neck bifurcation aneurysms.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolização Terapêutica Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolização Terapêutica Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2018 Tipo de documento: Article