Your browser doesn't support javascript.
loading
Effects of pulse width, waveform and current direction in the cortex: A combined cTMS-EEG study.
Casula, E P; Rocchi, L; Hannah, R; Rothwell, J C.
Afiliação
  • Casula EP; Sobell Department of Motor Neuroscience and Movement Disorders, University College London, London, United Kingdom; Non-invasive Brain Stimulation Unit, IRCCS Santa Lucia Foundation, Rome, Italy. Electronic address: elias.casula@gmail.com.
  • Rocchi L; Sobell Department of Motor Neuroscience and Movement Disorders, University College London, London, United Kingdom.
  • Hannah R; Sobell Department of Motor Neuroscience and Movement Disorders, University College London, London, United Kingdom.
  • Rothwell JC; Sobell Department of Motor Neuroscience and Movement Disorders, University College London, London, United Kingdom.
Brain Stimul ; 11(5): 1063-1070, 2018.
Article em En | MEDLINE | ID: mdl-29709505
BACKGROUND: the influence of pulse width, pulse waveform and current direction on transcranial magnetic stimulation (TMS) outcomes is of critical importance. However, their effects have only been investigated indirectly with motor-evoked potentials (MEP). By combining TMS and EEG it is possible to examine how these factors affect evoked activity from the cortex and compare that with the effects on MEP. OBJECTIVE: we used a new controllable TMS device (cTMS) to vary systematically pulse width, pulse waveform and current direction and explore their effects on global and local TMS-evoked EEG response. METHODS: In 19 healthy volunteers we measured (1) resting motor threshold (RMT) as an estimate of corticospinal excitability; (2) global mean field power (GMFP) as an estimate of global cortical excitability; and (3) local mean field power (LMFP) as an estimate of local cortical excitability. RESULTS: RMT was lower with monophasic posterior-to-anterior (PA) pulses that have a longer pulse width (p < 0.001). After adjusting for the individual motor threshold of each pulse type we found that (a) GMFP was higher with monophasic pulses (p < 0.001); (b) LMFP was higher with longer pulse width (p = 0.015); (c) early TEP polarity was modulated depending on the current direction (p = 0.01). CONCLUSIONS: Despite normalizing stimulus intensity to RMT, we found that local and global responses to TMS vary depending on pulse parameters. Since EEG responses can vary independently of the MEP, titrating parameters of TMS in relation to MEP threshold is not a useful way of ensuring that a constant set of neurons is activated within a cortical area.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potencial Evocado Motor / Estimulação Magnética Transcraniana / Córtex Motor Limite: Adult / Female / Humans / Male Idioma: En Revista: Brain Stimul Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potencial Evocado Motor / Estimulação Magnética Transcraniana / Córtex Motor Limite: Adult / Female / Humans / Male Idioma: En Revista: Brain Stimul Ano de publicação: 2018 Tipo de documento: Article