Your browser doesn't support javascript.
loading
Evaluation of the dosimetry approaches in ablation treatment of thyroid cancer.
Alan Selcuk, Nalan; Toklu, Turkay; Beykan, Seval; Karaaslan, Serife Ipek.
Afiliação
  • Alan Selcuk N; Department of Nuclear Medicine, Yeditepe University Hospital, Istanbul, Turkey.
  • Toklu T; Department of Nuclear Medicine, Yeditepe University Hospital, Istanbul, Turkey.
  • Beykan S; Department of Physics, Yeditepe University, Istanbul, Turkey.
  • Karaaslan SI; Department of Nuclear Medicine, University of Würzburg, Würzburg, Germany.
J Appl Clin Med Phys ; 19(4): 134-140, 2018 Jul.
Article em En | MEDLINE | ID: mdl-29858536
In this study, we aimed to evaluate dosimetric approaches in ablation treatment of Differentiated Thyroid Carcinoma (DTC) without interrupting the clinical routine. Prior to therapy, 10.7 MBq 131 I in average was orally given to 24 patients suffering from DTC. MIRD formalism was used for dosimetric calculations. For blood and bone marrow dosimetry, blood samples and whole-body counts were collected at 2, 24, 72, and 120 h after I-131 administration. For remnant tissue dosimetry, uptake measurements were performed at the same time intervals. To estimate the remnant volume, anterior and lateral planar gamma camera images were acquired with a reference source within the field of view at 24 h after I-131 administration. Ultrasound imaging was also performed. Treatment activities determined with the fixed activity method were administered to the patients. Secondary cancer risk relative to applied therapy was evaluated for dosimetric approaches. The average dose to blood and bone marrow were determined as 0.15 ± 0.04 and 0.11 ± 0.04 Gy/GBq, respectively. The average remnant tissue dose was 0.58 ± 0.52 Gy/MBq and the corresponding required activity to ablate the remnant was approximately 1.3 GBq of 131 I. A strong correlation between 24th-hour uptake and time-integrated activity coefficient values was obtained. Compared to fixed activity method, approximately five times higher secondary cancer risk was determined in bone marrow dosimetry, while the risk was about three times lower in lesion-based dosimetry.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Neoplasias da Glândula Tireoide Limite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: J Appl Clin Med Phys Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Neoplasias da Glândula Tireoide Limite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: J Appl Clin Med Phys Ano de publicação: 2018 Tipo de documento: Article