Brain Perfusion Measurements Using Multidelay Arterial Spin-Labeling Are Systematically Biased by the Number of Delays.
van der Thiel, M; Rodriguez, C; Giannakopoulos, P; Burke, M X; Lebel, R Marc; Gninenko, N; Van De Ville, D; Haller, S.
Afiliação
  • van der Thiel M; From the Faculty of Medicine of the University of Geneva (M.v.d.T., P.G., N.G., D.v.d.V., S.H.), Geneva, Switzerland.
  • Rodriguez C; Institute of Bioengineering (M.v.d.T., N.G., D.v.d.V.), School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
  • Giannakopoulos P; Division of Institutional Measures (C.R., P.G.), Medical Direction, University Hospitals of Geneva, Geneva, Switzerland.
  • Burke MX; From the Faculty of Medicine of the University of Geneva (M.v.d.T., P.G., N.G., D.v.d.V., S.H.), Geneva, Switzerland.
  • Lebel RM; Division of Institutional Measures (C.R., P.G.), Medical Direction, University Hospitals of Geneva, Geneva, Switzerland.
  • Gninenko N; GE Healthcare (M.X.B., M.L.), Little Chalfont, UK.
  • Van De Ville D; GE Healthcare (M.X.B., M.L.), Little Chalfont, UK.
  • Haller S; From the Faculty of Medicine of the University of Geneva (M.v.d.T., P.G., N.G., D.v.d.V., S.H.), Geneva, Switzerland.
AJNR Am J Neuroradiol ; 39(8): 1432-1438, 2018 08.
Article em En | MEDLINE | ID: mdl-29976831
ABSTRACT
BACKGROUND AND

PURPOSE:

Multidelay arterial spin-labeling is a promising emerging method in clinical practice. The effect of imaging parameters in multidelay arterial spin-labeling on estimated cerebral blood flow measurements remains unknown. We directly compared 3-delay versus 7-delay sequences, assessing the difference in the estimated transit time and blood flow. MATERIALS AND

METHODS:

This study included 87 cognitively healthy controls (78.7 ± 3.8 years of age; 49 women). We assessed delay and transit time-uncorrected and transit time-corrected CBF maps. Data analysis included voxelwise permutation-based between-sequence comparisons of 3-delay versus 7-delay, within-sequence comparison of transit time-uncorrected versus transit time-corrected maps, and average CBF calculations in regions that have been shown to differ.

RESULTS:

The 7-delay sequence estimated a higher CBF value than the 3-delay for the transit time-uncorrected and transit time-corrected maps in regions corresponding to the watershed areas (transit time-uncorrected = 27.62 ± 12.23 versus 24.58 ± 11.70 mL/min/100 g, Cohen's d = 0.25; transit time-corrected = 33.48 ± 14.92 versus 30.16 ± 14.32 mL/min/100 g, Cohen's d = 0.23). In the peripheral regions of the brain, the estimated delay was found to be longer for the 3-delay sequence (1.52408 ± 0.25236 seconds versus 1.47755 ± 0.24242 seconds, Cohen's d = 0.19), while the inverse was found in the center of the brain (1.39388 ± 0.22056 seconds versus 1.42565 ± 0.21872 seconds, Cohen's d = 0.14). Moreover, 7-delay had lower hemispheric asymmetry.

CONCLUSIONS:

The results of this study support the necessity of standardizing acquisition parameters in multidelay arterial spin-labeling and identifying basic parameters as a confounding factor in CBF quantification studies. Our findings conclude that multidelay arterial spin-labeling sequences with a high number of delays estimate higher CBF values than those with a lower number of delays.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Circulação Cerebrovascular / Neuroimagem Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Circulação Cerebrovascular / Neuroimagem Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2018 Tipo de documento: Article