Artificial Liver and Renal Support System for Cynomolgus Monkeys with Surgery-Induced Acute Renal Failure: A Preclinical Study.
Feng, Lei; He, Guolin; Cai, Lei; Fu, Chaoyi; Li, Yang; Weng, Jun; Huo, Xiaolin; Peng, Qing; Gao, Yi.
Afiliação
  • Feng L; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
  • He G; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
  • Cai L; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
  • Fu C; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
  • Li Y; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
  • Weng J; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
  • Huo X; Institute of Electrical Engineering, Chinese Academy of Science, Beijing 100190, China.
  • Peng Q; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
  • Gao Y; Department of Hepatobiliary Surgery II, Guangdong Provincial Research Center for Artificial Organ and Tissue Engineering, Guangzhou Clinical Research and Transformation Center for Artificial Liver, Institute of Regenerative Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou 510280,
Biomed Res Int ; 2018: 7456898, 2018.
Article em En | MEDLINE | ID: mdl-29992160
ABSTRACT
Renal dysfunction is one of the most common complications of liver cirrhosis and is associated with increased morbidity and mortality. However, no available technology can simultaneously support liver and renal function in these patients. The aim of this study was to evaluate the safety and efficacy of an artificial liver and renal support system in cynomolgus monkeys with surgery-induced ARF. The ARF model was established by ligature of bilateral renal arteries in eight cynomolgus monkeys, which were randomly divided into a treatment group (n = 4) and control group (n = 4). Biochemical indexes were determined before and after surgery. Blood endotoxin levels, biochemical indexes, and bacterial cultures were assessed at 0, 3, and 6 h during treatment. System pressures and vital signs were recorded at 1 h intervals. Pathological examination was performed after death. ARF was successfully established, based on significant elevation of biochemical indexes and pathological examination. The treatment group had significantly reduced biochemical indexes relative to the control group. Measurement of blood endotoxins and aerobic and anaerobic bacteria cultures indicated no bacterial growth. The system pressures and vital signs were stable during treatment. The results indicate that our support system for the treatment of cynomolgus monkeys with surgery-induced acute renal failure is safe and effective.
Assuntos

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Fígado Artificial / Injúria Renal Aguda Tipo de estudo: Etiology_studies Limite: Animals / Female / Humans / Male Idioma: En Revista: Biomed Res Int Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Fígado Artificial / Injúria Renal Aguda Tipo de estudo: Etiology_studies Limite: Animals / Female / Humans / Male Idioma: En Revista: Biomed Res Int Ano de publicação: 2018 Tipo de documento: Article