A novel high-frequency groundwater quality monitoring system.
Environ Monit Assess
; 190(8): 477, 2018 Jul 20.
Article
em En
| MEDLINE
| ID: mdl-30030629
High-frequency, long-term monitoring of water quality has revolutionized the study of surface waters in recent years. However, application of these techniques to groundwater has been limited by the ability to remotely pump and analyze groundwater. This paper describes a novel autonomous groundwater quality monitoring system which samples multiple wells to evaluate temporal changes and identify trends in groundwater chemistry. The system, deployed near Fresno, California, USA, collects and transmits high-frequency data, including water temperature, specific conductance, pH, dissolved oxygen, and nitrate, from supply and monitoring wells, in real-time. The system consists of a water quality sonde and optical nitrate sensor, manifold, submersible three-phase pump, variable frequency drive, data collection platform, solar panels, and rechargeable battery bank. The manifold directs water from three wells to a single set of sensors, thereby reducing setup and operation costs associated with multi-sensor networks. Sampling multiple wells at high frequency for several years provided a means of monitoring the vertical distribution and transport of solutes in the aquifer. Initial results show short period variability of nitrate, specific conductivity, and dissolved oxygen in the shallow aquifer, while the deeper portion of the aquifer remains unchanged-observations that may be missed with traditional discrete sampling approaches. In this aquifer system, nitrate and specific conductance are increasing in the shallow aquifer, while invariant changes in deep groundwater chemistry likely reflect relatively slow groundwater flow. In contrast, systems with high groundwater velocity, such as karst aquifers, have been shown to exhibit higher-frequency groundwater chemistry changes. The stability of the deeper aquifer over the monitoring period was leveraged to develop estimates of measurement system uncertainty, which were typically lower than the manufacturer's stated specifications, enabling the identification of subtle variability in water chemistry that may have otherwise been missed.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Contexto em Saúde:
12_ODS3_hazardous_contamination
/
2_ODS3
Base de dados:
MEDLINE
Assunto principal:
Poluentes Químicos da Água
/
Água Subterrânea
/
Qualidade da Água
/
Monitoramento Ambiental
Tipo de estudo:
Prognostic_studies
País/Região como assunto:
America do norte
Idioma:
En
Revista:
Environ Monit Assess
Ano de publicação:
2018
Tipo de documento:
Article