Your browser doesn't support javascript.
loading
Mapping anisotropy improves QCT-based finite element estimation of hip strength in pooled stance and side-fall load configurations.
Panyasantisuk, J; Dall'Ara, E; Pretterklieber, M; Pahr, D H; Zysset, P K.
Afiliação
  • Panyasantisuk J; Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland.
  • Dall'Ara E; Department of Oncology and Metabolism and INSIGNEO, Institute for in silico Medicine, University of Sheffield, United Kingdom.
  • Pretterklieber M; Division of Anatomy, Medical University of Vienna, Austria.
  • Pahr DH; Institute for Lightweight Design and Structural Biomechanics, Vienna University of Technology, Austria; Department for Anatomy and Biomechanics, Karl Landsteiner Private University for Health Sciences, Austria.
  • Zysset PK; Institute for Surgical Technology and Biomechanics, University of Bern, Switzerland. Electronic address: philippe.zysset@istb.unibe.ch.
Med Eng Phys ; 59: 36-42, 2018 09.
Article em En | MEDLINE | ID: mdl-30131112
ABSTRACT
Hip fractures are one of the most severe consequences of osteoporosis. Compared to the clinical standard of DXA-based aBMD at the femoral neck, QCT-based FEA delivers a better surrogate of femoral strength and gains acceptance for the calculation of hip fracture risk when a CT reconstruction is available. Isotropic, homogenised voxel-based, finite element (hvFE) models are widely used to estimate femoral strength in cross-sectional and longitudinal clinical studies. However, fabric anisotropy is a classical feature of the architecture of the proximal femur and the second determinant of the homogenised mechanical properties of trabecular bone. Due to the limited resolution, fabric anisotropy cannot be derived from clinical CT reconstructions. Alternatively, fabric anisotropy can be extracted from HR-pQCT images of cadaveric femora. In this study, fabric anisotropy from HR-pQCT images was mapped onto QCT-based hvFE models of 71 human proximal femora for which both HR-pQCT and QCT images were available. Stiffness and ultimate load computed from anisotropic hvFE models were compared with previous biomechanical tests in both stance and side-fall configurations. The influence of using the femur-specific versus a mean fabric distribution on the hvFE predictions was assessed. Femur-specific and mean fabric enhance the prediction of experimental ultimate force for the pooled, i.e. stance and side-fall, (isotropic r2=0.81, femur-specific fabric r2=0.88, mean fabric r2=0.86,p<0.001) but not for the individual configurations. Fabric anisotropy significantly improves bone strength prediction for the pooled configurations, and mapped fabric provides a comparable prediction to true fabric. The mapping of fabric anisotropy is therefore expected to help generate more accurate QCT-based hvFE models of the proximal femur for personalised or multiple load configurations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Análise de Elementos Finitos / Quadril Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Med Eng Phys Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Análise de Elementos Finitos / Quadril Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Med Eng Phys Ano de publicação: 2018 Tipo de documento: Article