A new acute scaphoid fracture assessment method: a reliability study of the 'long axis' measurement.
Dean, Benjamin J F; Riley, Nicholas D; McCulloch, Earl Robert; Lane, Jennifer C E; Touzell, Amy Beth; Graham, Alastair J.
Afiliação
  • Dean BJF; Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Botnar Research Centre, Windmill road, Oxford, OX3 7LD, UK. bendean1979@gmail.com.
  • Riley ND; Nuffield Orthopaedic Centre, Windmill road, Oxford, OX3 7LD, UK. bendean1979@gmail.com.
  • McCulloch ER; Nuffield Orthopaedic Centre, Windmill road, Oxford, OX3 7LD, UK.
  • Lane JCE; Nuffield Orthopaedic Centre, Windmill road, Oxford, OX3 7LD, UK.
  • Touzell AB; Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Botnar Research Centre, Windmill road, Oxford, OX3 7LD, UK.
  • Graham AJ; Nuffield Orthopaedic Centre, Windmill road, Oxford, OX3 7LD, UK.
BMC Musculoskelet Disord ; 19(1): 310, 2018 Aug 29.
Article em En | MEDLINE | ID: mdl-30157835
ABSTRACT

BACKGROUND:

The aim of this study was to assess the inter observer and intra observer reliability of acute scaphoid fracture classification methods including a novel 'long axis' measurement, a simple method which we have developed with the aim of improving agreement when describing acute fractures.

METHODS:

We identified sixty patients with acute scaphoid fractures at two centres who had been investigated with both plain radiographs and a CT (Computed Tomography) scan within 4 weeks of injury. The fractures were assessed by three observers at each centre using three commonly used classification systems and the 'long axis' method.

RESULTS:

Inter observer reliability based on X-rays the 'long axis' measurement demonstrated substantial agreement (Intraclass Correlation Coefficient (ICC) =0.76) and was significantly more reliable than the Mayo (p < 0.01), the most reliable of the established classification systems with moderate levels of agreement (kappa = 0.56). Intra observer reliability the long axis measurement demonstrated almost perfect agreement whether based on X-ray (ICC = 0.905) or CT (ICC = 0.900).

CONCLUSIONS:

This study describes a novel pragmatic 'long axis' method for the assessment of acute scaphoid fractures which demonstrates substantial inter and intra observer reliability. The 'long axis' measurement has clear potential benefits over traditional classification systems which should be explored in future clinical research.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traumatismos do Punho / Tomografia Computadorizada por Raios X / Osso Escafoide / Fraturas Ósseas Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: BMC Musculoskelet Disord Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traumatismos do Punho / Tomografia Computadorizada por Raios X / Osso Escafoide / Fraturas Ósseas Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: BMC Musculoskelet Disord Ano de publicação: 2018 Tipo de documento: Article