Improvement of reverse sequence algorithm for syphilis diagnosis using optimal treponemal screening assay signal-to-cutoff ratio.
Serhir, Bouchra; Labbé, Annie-Claude; Doualla-Bell, Florence; Simard, Marc; Lambert, Gilles; Trudelle, Annick; Longtin, Jean; Tremblay, Cécile; Fortin, Claude.
Afiliação
  • Serhir B; Laboratoire de santé publique du Québec/Institut national de santé publique du Québec, Sainte-Anne-de-Bellevue, Québec, Canada.
  • Labbé AC; CIUSSS de l'Est-de-l'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Service de Maladies infectieuses et microbiologie médicale, Montréal, Canada.
  • Doualla-Bell F; Laboratoire de santé publique du Québec/Institut national de santé publique du Québec, Sainte-Anne-de-Bellevue, Québec, Canada.
  • Simard M; Unité de surveillance des maladies chroniques et de leur déterminants/Institut national de santé publique du Québec, Québec, Québec, Canada.
  • Lambert G; Unité des infections transmissibles sexuellement et par le sang/Institut national de santé publique du Québec, Montréal, Québec, Canada.
  • Trudelle A; Laboratoire de santé publique du Québec/Institut national de santé publique du Québec, Sainte-Anne-de-Bellevue, Québec, Canada.
  • Longtin J; Laboratoire de santé publique du Québec/Institut national de santé publique du Québec, Sainte-Anne-de-Bellevue, Québec, Canada.
  • Tremblay C; Centre hospitalier de l'Université de Montréal, Département de microbiologie médicale et infectiologie, Montréal, Québec, Canada.
  • Fortin C; Centre hospitalier de l'Université de Montréal, Département de microbiologie médicale et infectiologie, Montréal, Québec, Canada.
PLoS One ; 13(9): e0204001, 2018.
Article em En | MEDLINE | ID: mdl-30212544
BACKGROUND: Although reverse sequence algorithms (RSA) for syphilis screening are performing well, they still have to rely on treponemal confirmatory tests at least for sera reactive by enzyme immunoassay/chemiluminescence immunoassay (EIA/CIA) and unreactive by rapid plasma reagin (RPR). Quebec's laboratory network previously showed that 3.3% of EIA/CIA reactive and weakly-reactive RPR samples (RPR titer of 1 to 4) would have been misclassified as syphilis cases if a treponemal confirmatory test had not been performed. OBJECTIVES: To correlate the magnitude of signal-to-cutoff (S/CO) ratios of the 4 most used commercial first-line EIA/CIA kits in Quebec with syphilis confirmation results and establish a S/CO value above which treponemal confirmation would not be required. METHODS: Serum samples from previously undiagnosed individuals (n = 7 404) obtained between January 2014 and February 2017 that were reactive by EIA/CIA and either negative by RPR or reactive with a low titer (1 to 4) were included in the study. All samples were tested with Treponema pallidum particle agglutination (TP-PA) and, if negative or inconclusive, with a line immunoassay (LIA). Syphilis infection confirmation was defined by a reactive TP-PA or LIA. Logistic regression analysis was used to determine S/CO values (95% CI lower bound = 0.98) above which confirmation would not be required. The four kits studied were Architect TP, BioPlex IgG, Syphilis EIA II, and Trep-Sure. RESULTS: Of 2609 reactive EIA/CIA specimens tested for the determination of S/CO values, 1730 (66%) were confirmed as true syphilis cases. Confirmation rate was significantly higher in samples with low-titer positive RPR (92%) than with negative RPR samples (54%); p<0.01. A linear probability model (95% CI lower bound = 0.98) predicted the S/CO value above which a confirmation would no longer be needed for the Architect TP (16.4), Bioplex IgG (7.4) and Trep-Sure (24.6). No linearity was observed between the S/CO value of Syphilis EIA II and the confirmation rate. The validity of the predicted S/CO values was investigated using 4 795 specimens. The use of an S/CO value of 16.4 with the Architect TP kit and of 24.6 for the Trep-Sure kit would obviate the need for confirmation of 18.5% and 13.2% of sera from the all RPR subgroup, respectively. For the BioPlex IgG kit, 81.1% of sera would not require confirmation when using the S/CO value of 7.4 in the low titer RPR subgroup. CONCLUSION: Signal-to-cut-off values could be used to identify sera that do not require extra treponemal confirmation for 3 of the 4 most used first-line EIA/CIA kits in Quebec. Using these values in our current reverse screening algorithm (RSA) would avoid the need for confirmatory tests in 14 to 20% of sera, a proportion that could reach 75% among low-titer RPR.
Assuntos

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Sorodiagnóstico da Sífilis / Sífilis Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans País/Região como assunto: America do norte Idioma: En Revista: PLoS One Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Sorodiagnóstico da Sífilis / Sífilis Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans País/Região como assunto: America do norte Idioma: En Revista: PLoS One Ano de publicação: 2018 Tipo de documento: Article