Your browser doesn't support javascript.
loading
Data on groundwater quality, scaling potential and corrosiveness of water samples in Torbat-e-Heydariyeh rural drinking water resources, Khorasan-e-Razavi province, Iran.
Babaeia, A A; Goudarzi, Gh; Khodadadi, Rouhollah; Jalili, Davoud; Radfard, Majid; Biglari, Hamed; Abasnia, Abbas; Mirzabeigi, Arefeh.
Afiliação
  • Babaeia AA; Environmental Technologies Research Center (ETRC), Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Goudarzi G; Associate Professor, Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Khodadadi R; Department of Environmental Health Engineering, School of Health, Student Research Office, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Jalili D; Department of Environmental Health Engineering, School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Radfard M; Department of Environmental Health Engineering, School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Biglari H; Health deputy shahrekord University of Medical Sciences, shahrekord, Iran.
  • Abasnia A; Health Research Center, Life Stayle institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
  • Mirzabeigi A; Department of Environmental Health Engineering, School of Public Health, Gonabad University of Medical Sciences, Gonabad, Iran.
Data Brief ; 19: 2260-2266, 2018 Aug.
Article em En | MEDLINE | ID: mdl-30246094
ABSTRACT
According to World Health Organization guidelines, corrosion control is an important aspect of safe drinking-water supplies. The data presented is physical and chemical parameters of drinking water in the rural areas of Torbat-e-Heydariyeh city, also to determine corrosion indices. This cross-sectional study has carried out with 188 taken samples during 2014 with 13 parameters, which has been analyzed based on standard method. Also with regard to standard conditions, result of this paper is compared with Environmental Protection Agency and Iran national standards. Five indices, Langlier Saturation Index (LSI), Ryznar Stability Index (RSI), Puckorius Scaling Index (PSI), Larson-Skold Index (LS) and Aggressive Index (AI), programmed by using Microsoft Excel software. Owing to its simplicity, the program can easily be used by researchers and operators. Parameters included Sulfate, Sodium, Chloride, and Electrical Conductivity respectively was 13.5%, 28%, 10.5%, and 15% more than standard level. The amounts of Nitrate, in 98% of cases were in permissible limits and about 2% were more than standard level. Result of presented research indicate that water is corrosive at 10.6%, 89.4%, 87.2%, 59.6% and 14.9% of drinking water supply reservoirs, according to LSI, RSI, PSI, LS and AI, respectively.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Data Brief Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Data Brief Ano de publicação: 2018 Tipo de documento: Article