Your browser doesn't support javascript.
loading
A novel micro-extraction strategy for extraction of bisphosphonates from biological fluids using zirconia nanoparticles coupled with spectrofluorimetry and high performance liquid chromatography.
Rahbar, Nadereh; Nazernezhad, Ladan; Asadinezhad, Maryam; Ramezani, Zahra; Kouchak, Maryam.
Afiliação
  • Rahbar N; Nanotechnology Research Center, Faculty of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Nazernezhad L; Medicinal Chemistry Department, Faculty of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Asadinezhad M; Medicinal Chemistry Department, Faculty of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Ramezani Z; Department of Chemistry, Science and Research Branch, Islamic Azad University, Khouzestan, Iran.
  • Kouchak M; Nanotechnology Research Center, Faculty of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
J Food Drug Anal ; 26(4): 1303-1311, 2018 10.
Article em En | MEDLINE | ID: mdl-30249329
ABSTRACT
Extraction of bisphosphonates from biological fluids is important and time consuming step in sample preparation procedure. This paper describes a simple and green sample preparation technique for dispersive micro solid phase extraction (DMSPE) of alendronate sodium (ALS) from urine and serum samples prior to direct spectrofluorimetry (DSFL) and high performance liquid chromatography with fluorescence detection (HPLC-FLD), respectively. The DMSPE strategy is based on the selective chemisorption of ALS on zirconia nanoparticles (ZNPs) as an adsorbent followed by derivatization of the eluted analyte using o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol (2ME) at basic medium to form fluorescent species. The chemical and instrumental influencing parameters on DMSPE and measuring methods were optimized for the efficient extraction and determination of ALS. The presented methods were capable of extracting ALS from human urine and serum samples and determining over the wide ranges of 5-1000 and 5-2500 µg L-1 with limits of detection (LOD) of 1.5 and 1.4 µg L-1 for DSFL and HPLC methods, respectively. The relative recoveries for the three spiked standard levels of ALS in urine and serum samples ranged from 89.0% to 107.0%, and the intra-day relative standard deviations (%RSDs) were in the range of 2.9-7.9%.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Urina / Cromatografia Líquida de Alta Pressão / Alendronato / Soro / Microextração em Fase Sólida Tipo de estudo: Evaluation_studies Limite: Humans Idioma: En Revista: J Food Drug Anal Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Urina / Cromatografia Líquida de Alta Pressão / Alendronato / Soro / Microextração em Fase Sólida Tipo de estudo: Evaluation_studies Limite: Humans Idioma: En Revista: J Food Drug Anal Ano de publicação: 2018 Tipo de documento: Article