Your browser doesn't support javascript.
loading
Application of portable near-infrared spectrometer to Heliotron J plasma diagnostics.
Kado, S; Iwata, A; Kanazawa, T; Okada, H; Yamamoto, S; Motojima, G; Okazaki, H; Minami, T; Kobayashi, S; Nagasaki, K; Ohshima, S; Nakamura, Y; Ishizawa, A; Konoshima, S; Mizuuchi, T.
Afiliação
  • Kado S; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Iwata A; Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Kanazawa T; Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Okada H; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Yamamoto S; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Motojima G; National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, Gifu 509-5292, Japan.
  • Okazaki H; Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Minami T; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Kobayashi S; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Nagasaki K; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Ohshima S; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Nakamura Y; Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Ishizawa A; Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Konoshima S; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Mizuuchi T; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
Rev Sci Instrum ; 89(10): 10D129, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30399947
ABSTRACT
A simple near-infrared (NIR) spectrometer with a wavelength range of 898-2130 nm has recently been applied to diagnose Heliotron J plasmas. It adopts a symmetrical crossed Czerny-Turner mount equipped with a thermoelectrically cooled 512 channel InGaAs linear sensor. Reciprocal linear dispersion was deduced to 96.37 nm/mm at the center of the detector. External filters can be inserted into the path of the collection optics to reject second-order spectra, as needed. Absolute intensity calibration was performed together with a visible spectrometer using a tungsten halogen lamp, and the effect of the transmittance fringe in the visible region of the applied long-pass filter on the NIR calibration was investigated. The intended application of the NIR spectrometer includes extending the wavelength region of a spectral monitor to less contaminated regions for Heliotron J plasma studies. In preliminary measurements, we observed the Paschen series for the hydrogen pellet injection plasma and two atomic helium lines, i.e., 2S-2P singlet and triplet lines, in helium gas puffing experiments. A continuum spectrum in this regime that is attributable to black-body radiation from hot spots on the plasma-facing components was identified. In addition, this may also be used to monitor background radiation in the YAG-Thomson scattering signals near 1064 nm.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article