Your browser doesn't support javascript.
loading
Ionic liquid dispersive liquid-liquid microextraction combined with LC-UV-Vis for the fast and simultaneous determination of cortisone and cortisol in human saliva samples.
Abujaber, Feras; Corps Ricardo, Ana Isabel; Ríos, Ángel; Guzmán Bernardo, Francisco Javier; Rodríguez Martín-Doimeadios, Rosa C.
Afiliação
  • Abujaber F; Environmental Sciences Institute (ICAM), Department of Analytical Chemistry and Food Technology, University of Castilla-La Mancha, Avda. Carlos III s/n, 45071 Toledo, Spain.
  • Corps Ricardo AI; Environmental Sciences Institute (ICAM), Department of Analytical Chemistry and Food Technology, University of Castilla-La Mancha, Avda. Carlos III s/n, 45071 Toledo, Spain.
  • Ríos Á; Faculty of Chemical Sciences and Technologies, Department of Analytical Chemistry and Food Technology, University of Castilla-La Mancha, Avda. Camilo José Cela s/n, 13071 Ciudad Real, Spain.
  • Guzmán Bernardo FJ; Environmental Sciences Institute (ICAM), Department of Analytical Chemistry and Food Technology, University of Castilla-La Mancha, Avda. Carlos III s/n, 45071 Toledo, Spain.
  • Rodríguez Martín-Doimeadios RC; Environmental Sciences Institute (ICAM), Department of Analytical Chemistry and Food Technology, University of Castilla-La Mancha, Avda. Carlos III s/n, 45071 Toledo, Spain. Electronic address: rosacarmen.rodriguez@uclm.es.
J Pharm Biomed Anal ; 165: 141-146, 2019 Feb 20.
Article em En | MEDLINE | ID: mdl-30530250
ABSTRACT
Ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) was used for the first time for the extraction and preconcentration of cortisone and cortisol from human saliva samples. This approach allows the determination of both compounds by liquid chromatography (LC) with ultra-violet/visible (UV/Vis) detection at physiological levels. The IL 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] and methanol (MeOH) were used as extraction and dispersive solvents, respectively. The parameters that affect extraction (ionic strength, pH, amount of IL, volume of dispersive solvent, vortex and centrifugation time) were optimized. Limits of detection were 0.11 (cortisone) and 0.16 µg L-1 (cortisol) and enrichment factors of 5.0 (cortisol) and 6.3 (cortisone) were achieved. Recoveries from 83.3 ± 1.6 to 115.8 ± 3.0% were obtained for the extraction of the target analytes in spiked human saliva samples. Intraday and interday precision, expressed as relative standard deviation, was below 4.2 and 7.8% for cortisone and cortisol, respectively. The method was successfully applied to the determination of cortisone and cortisol in saliva from healthy volunteers (n = 9) in the morning and in the evening. The method is simple, faster, and more environmentally friendly than the current ones.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cortisona / Hidrocortisona / Cromatografia Líquida / Microextração em Fase Líquida Limite: Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cortisona / Hidrocortisona / Cromatografia Líquida / Microextração em Fase Líquida Limite: Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article