Your browser doesn't support javascript.
loading
A Cross-Sectional Study Examining the Correlation between Nocturnal Melatonin Level and Sleep Quality in Patients Admitted To the Cardiac Care Unit.
Kamkar, Mohammad Zaman; Khorshidi, Sommayeh Rezvani; Maddah, Seideh Mahrokh Alinaghi; Emami Zeydi, Amir; Modanloo, Mahnaz.
Afiliação
  • Kamkar MZ; Department of Psychiatry, Golestan Research Center of Psychiatry, Golestan University of Medical Sciences, Gorgan, Iran.
  • Khorshidi SR; Department of Medical-Surgical Nursing, Faculty of Nursing and Midwifery, Golestan University of Medical Sciences, Gorgan, Iran.
  • Maddah SMA; Department of Anesthesiology, Faculty of Medicine, Golestan University of Medical Sciences, Gorgan, Iran.
  • Emami Zeydi A; Department of Medical-Surgical Nursing, Nasibeh School of Nursing and Midwifery, Mazandaran University of Medical Sciences, Sari, Iran.
  • Modanloo M; Nursing Research Center, Golestan University of Medical Sciences, Gorgan, Iran.
Open Access Maced J Med Sci ; 6(12): 2342-2347, 2018 12 20.
Article em En | MEDLINE | ID: mdl-30607188
ABSTRACT

BACKGROUND:

Quality of sleep, as a basic need, is an important factor for surviving patients in hospitals. Many factors may contribute to disturbing patients sleep, such as continuous ambient light, is required for healthcare providers to monitor patients. Ambient light can influence patients' quality of sleep due to melatonin secretion.

AIM:

Study aimed to determine the correlation between nocturnal melatonin levels and sleep quality in patients admitted to the Cardiac Care Units (CCU). MATERIAL AND

METHODS:

This cross-sectional study was done on inpatients of CCUs at Amir-Almomenin Hospital in Kordkoy city, a cardiac referral hospital in the northeastern of Iran in 2015. Sixty-eight inpatients were selected through convenience sampling. Before data gathering light level of CCUs was measured every one hour in 2 days, the quality of nocturnal sleep was investigated through Verran and Snyder-Halpern (VSH) Sleep Scale at the second night of admission urinary melatonin level was measured at the same night in all urine excreted between 2200 pm and 0700 am.

RESULTS:

The mean and standard deviation (SD) score of sleep quality in three dimensions of sleep disturbance, sleep effectiveness and sleep supplementation were 336.6 ± 149.9, 269.0 ± 82.2, and 175.2 ± 30.7, respectively. Also, the mean and SD of nocturnal urinary melatonin levels was 323.02 ± 136.21 pg/ml. There was not a significant correlation between level of nocturnal melatonin and three domains of sleep quality; sleep disturbance (r = 0.005, P = 0.968), sleep effectiveness (r = 0.090, P = 0.464), and sleep supplementation (r = -0.037, P = 0.763).

CONCLUSION:

According to the result, most CCUs patients suffer from sleep disturbance. However, there was no correlation between the level of melatonin and sleep quality. There is a need for recognising the reasons for sleep disturbances in Cardiac Care Units. It is imperative for care providers to be able to recognise the causes of sleep disturbances and to modify environmental factors such as ambient light to improve sleep quality in hospitalised patients.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prevalence_studies Idioma: En Revista: Open Access Maced J Med Sci Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prevalence_studies Idioma: En Revista: Open Access Maced J Med Sci Ano de publicação: 2018 Tipo de documento: Article