Compact, modular and in-plane AOSLO for high-resolution retinal imaging.
Young, Laura K; Morris, Timothy J; Saunter, Christopher D; Smithson, Hannah E.
Afiliação
  • Young LK; Department of Experimental Psychology, University of Oxford, 15 Parks Road, Oxford OX1 3PH, UK.
  • Morris TJ; Department of Physics, Durham University, South Road, Durham DH1 3LE, UK.
  • Saunter CD; Department of Physics, Durham University, South Road, Durham DH1 3LE, UK.
  • Smithson HE; Department of Physics, Durham University, South Road, Durham DH1 3LE, UK.
Biomed Opt Express ; 9(9): 4275-4293, 2018 Sep 01.
Article em En | MEDLINE | ID: mdl-30615719
ABSTRACT
The adaptive optics scanning laser ophthalmoscope (AOSLO) was first developed in 2002 and since then the technology has been adopted in several laboratories around the world, for both clinical and psychophysical research. There have been a few major design implementations of the AOSLO. The first used on-axis tilted spherical mirrors in a planar arrangement, and the second minimized the build up of astigmatism present in the first design by using a non-planar arrangement. Other designs have avoided astigmatism by using custom-made toroidal mirrors or by using lenses on-axis, rather than mirrors. We present a new design implementation for an AOSLO that maintains a planar optical alignment without the build up astigmatism using compact, reconfigurable modules based on an Offner relay system. We additionally use an off-the-shelf digital oscilloscope for data capture and custom-written Python code for generating and analyzing the retinal images. This design results in a compact system that is simple to align and, being composed of modular relays, has the potential for additional components to be added. We show that this system maintains diffraction-limited image quality across the field of view and that cones are clearly resolved in the central retina. The modular relay design is generally applicable to any system requiring one or more components in the pupil conjugate plane. This is likely to be useful for any point-scanned system, such as a standard scanning laser ophthalmoscope or non-ophthalmic confocal imaging system.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Biomed Opt Express Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Biomed Opt Express Ano de publicação: 2018 Tipo de documento: Article