Your browser doesn't support javascript.
loading
Analytical validation of real-time quantitative PCR assays for optimum diagnosis of vivax malaria.
Almeida-de-Oliveira, Natália Ketrin; Moreira, Otacílio C; de Lavigne, Aline Rosa; Mendonça-Lima, Leila; Werneck, Guilherme Loureiro; Daniel-Ribeiro, Cláudio Tadeu; Ferreira-da-Cruz, Maria de Fátima.
Afiliação
  • Almeida-de-Oliveira NK; Fundação Oswaldo Cruz-Fiocruz, Instituto Oswaldo Cruz, Laboratório de Pesquisa em Malária, Rio de Janeiro, RJ, Brasil.
  • Moreira OC; Fundação Oswaldo Cruz-Fiocruz, Instituto Oswaldo Cruz, Laboratório de Biologia Molecular e Doenças Endêmicas, Rio de Janeiro, RJ, Brasil.
  • de Lavigne AR; Fundação Oswaldo Cruz-Fiocruz, Instituto Oswaldo Cruz, Laboratório de Pesquisa em Malária, Rio de Janeiro, RJ, Brasil.
  • Mendonça-Lima L; Fundação Oswaldo Cruz-Fiocruz, Instituto Oswaldo Cruz, Laboratório de Genômica Funcional e Bioinformática, Rio de Janeiro, RJ, Brasil.
  • Werneck GL; Universidade do Estado do Rio de Janeiro, Instituto de Medicina Social, Departamento de Epidemiologia, Rio de Janeiro, RJ, Brasil.
  • Daniel-Ribeiro CT; Fundação Oswaldo Cruz-Fiocruz, Instituto Oswaldo Cruz, Laboratório de Pesquisa em Malária, Rio de Janeiro, RJ, Brasil.
  • Ferreira-da-Cruz MF; Fundação Oswaldo Cruz-Fiocruz, Instituto Oswaldo Cruz, Laboratório de Pesquisa em Malária, Rio de Janeiro, RJ, Brasil.
Mem Inst Oswaldo Cruz ; 114: e180350, 2019 Jan 31.
Article em En | MEDLINE | ID: mdl-30726341
BACKGROUND: The prompt diagnosis of plasmodial species for effective treatment prevents worsening of individual health and avoids transmission maintenance or even malaria reintroduction in areas where Plasmodium does not exist. Polymerase chain reaction (PCR) allows for the detection of parasites below the threshold of microscopic examination. OBJECTIVE: Our aim was to develop a real-time PCR test to reduce diagnostic errors and increase efficacy. METHODS: The lower limit of quantification and the linearity/analytical sensitivity to measure sensitivity or limit of detection (LoD) were determined. Intra-assay variations (repeatability) and alterations between assays, operators, and instruments (reproducibility) were also assessed to set precision. FINDINGS: The linearity in SYBR™ Green and TaqMan™ systems was 106 and 102 copies and analytical sensitivity 1.13 and 1.17 copies/µL, respectively. Real-time PCR was more sensitive than conventional PCR, showing a LoD of 0.01 parasite (p)/µL. Reproducibility and repeatability (precision) were 100% for up to 0.1 p/µL in SYBR™ Green and 1 p/µL in TaqMan™ and conventional PCR. CONCLUSION: Real-time PCR may replace conventional PCR in reference laboratories for P. vivax detection due to its rapidity. The TaqMan™ system is the most indicated when quantification assays are required. Performing tests in triplicate when diagnosing Plasmodium-infected-asymptomatic individuals is recommended to minimise diagnostic errors.
Assuntos

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 / 3_ND Base de dados: MEDLINE Assunto principal: Plasmodium vivax / DNA de Protozoário / Malária Vivax Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Mem Inst Oswaldo Cruz Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 / 3_ND Base de dados: MEDLINE Assunto principal: Plasmodium vivax / DNA de Protozoário / Malária Vivax Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Mem Inst Oswaldo Cruz Ano de publicação: 2019 Tipo de documento: Article