Your browser doesn't support javascript.
loading
No time for drifting: Comparing performance and applicability of signal detrending algorithms for real-time fMRI.
Kopel, R; Sladky, R; Laub, P; Koush, Y; Robineau, F; Hutton, C; Weiskopf, N; Vuilleumier, P; Van De Ville, D; Scharnowski, F.
Afiliação
  • Kopel R; Department of Radiology and Medical Informatics, CIBM, University of Geneva, Geneva, Switzerland; Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Sladky R; Department of Psychiatric, Psychotherapy and Psychosomatics, Psychiatric Hospital, University of Zürich, Zürich, Switzerland; Social, Cognitive and Affective Neuroscience Unit, Department of Basic Psychological Research and Research Methods, Faculty of Psychology, University of Vienna, Vienna, Austr
  • Laub P; Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Koush Y; Department of Radiology and Medical Informatics, CIBM, University of Geneva, Geneva, Switzerland; Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland; Department of Radiology and Medical Imaging, Yale University, New Haven, USA.
  • Robineau F; Laboratory for Behavioral Neurology and Imaging of Cognition, Department of Neuroscience, University Medical Center, Geneva, Switzerland; Geneva Neuroscience Center, Geneva, Switzerland.
  • Hutton C; Wellcome Trust Centre for Neuroimaging, UCL Institute of Neurology, University College London, London, UK.
  • Weiskopf N; Geneva Neuroscience Center, Geneva, Switzerland; Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Vuilleumier P; Laboratory for Behavioral Neurology and Imaging of Cognition, Department of Neuroscience, University Medical Center, Geneva, Switzerland; Geneva Neuroscience Center, Geneva, Switzerland.
  • Van De Ville D; Department of Radiology and Medical Informatics, CIBM, University of Geneva, Geneva, Switzerland; Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Scharnowski F; Department of Radiology and Medical Informatics, CIBM, University of Geneva, Geneva, Switzerland; Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland; Department of Psychiatric, Psychotherapy and Psychosomatics, Psychiatric Hospital, University of Züri
Neuroimage ; 191: 421-429, 2019 05 01.
Article em En | MEDLINE | ID: mdl-30818024
ABSTRACT
As a consequence of recent technological advances in the field of functional magnetic resonance imaging (fMRI), results can now be made available in real-time. This allows for novel applications such as online quality assurance of the acquisition, intra-operative fMRI, brain-computer-interfaces, and neurofeedback. To that aim, signal processing algorithms for real-time fMRI must reliably correct signal contaminations due to physiological noise, head motion, and scanner drift. The aim of this study was to compare performance of the commonly used online detrending algorithms exponential moving average (EMA), incremental general linear model (iGLM) and sliding window iGLM (iGLMwindow). For comparison, we also included offline detrending algorithms (i.e., MATLAB's and SPM8's native detrending functions). Additionally, we optimized the EMA control parameter, by assessing the algorithm's performance on a simulated data set with an exhaustive set of realistic experimental design parameters. First, we optimized the free parameters of the online and offline detrending algorithms. Next, using simulated data, we systematically compared the performance of the algorithms with respect to varying levels of Gaussian and colored noise, linear and non-linear drifts, spikes, and step function artifacts. Additionally, using in vivo data from an actual rt-fMRI experiment, we validated our results in a post hoc offline comparison of the different detrending algorithms. Quantitative measures show that all algorithms perform well, even though they are differently affected by the different artifact types. The iGLM approach outperforms the other online algorithms and achieves online detrending performance that is as good as that of offline procedures. These results may guide developers and users of real-time fMRI analyses tools to best account for the problem of signal drifts in real-time fMRI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Encéfalo / Imageamento por Ressonância Magnética / Artefatos Limite: Humans Idioma: En Revista: Neuroimage Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Encéfalo / Imageamento por Ressonância Magnética / Artefatos Limite: Humans Idioma: En Revista: Neuroimage Ano de publicação: 2019 Tipo de documento: Article