Your browser doesn't support javascript.
loading
The effect of membrane thickness on supported liquid membrane extractions in-line coupled to capillary electrophoresis for analyses of complex samples.
Rysavá, Lenka; Dvorák, Milos; Kubán, Pavel.
Afiliação
  • Rysavá L; Institute of Analytical Chemistry of the Czech Academy of Sciences, Veverí 97, CZ-60200 Brno, Czech Republic; Institute of Food Science and Biotechnology, Faculty of Chemistry, Brno University of Technology, Purkynova 118, CZ-61200, Brno, Czech Republic.
  • Dvorák M; Institute of Analytical Chemistry of the Czech Academy of Sciences, Veverí 97, CZ-60200 Brno, Czech Republic.
  • Kubán P; Institute of Analytical Chemistry of the Czech Academy of Sciences, Veverí 97, CZ-60200 Brno, Czech Republic. Electronic address: kuban@iach.cz.
J Chromatogr A ; 1596: 226-232, 2019 Jul 05.
Article em En | MEDLINE | ID: mdl-30853166
ABSTRACT
The effect of membrane thickness on extraction performance was systematically examined in extractions through supported liquid membranes (SLM), which were in-line coupled to capillary electrophoresis (CE). Three porous polypropylene membranes with different thickness (25, 100 and 170 µm) were used as supports for SLM extractions of model basic drugs (nortriptyline, papaverine, haloperidol and loperamide) from complex samples. The analytes were transferred through the SLMs by a pH gradient and were in-line injected, separated and quantified using a commercial CE instrument with ultraviolet (UV) detection. Transfers of the model drugs through SLM decreased with the increased membrane thickness (in the order 25 > 100 > 170 µm) and highest transfers were achieved for the thinnest membrane. Interferences from complex sample matrices were efficiently eliminated, moreover, impregnation of the 25 µm membrane required significantly reduced volume of organic solvent. Mechanical stability of the impregnated 25 µm membrane was excellent during in-line injections, which necessitated direct contact of CE separation capillary with the SLM. Repeatability of the hyphenated SLM-CE-UV method (using the 25 µm membrane) was lower than 11% (RSD values of peak areas) and calibration curves were strictly linear in 0.5-30 µg/mL concentration range (coefficients of determination ≥ 0.997). Transfers of the basic drugs from donor solutions (standard and undiluted human urine/plasma) through the SLMs ranged from 45 to 231% and limits of detection were between 0.02 and 0.15 µg/mL.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Líquidos Corporais / Urinálise / Eletroforese Capilar / Membranas Artificiais Limite: Humans Idioma: En Revista: J Chromatogr A Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Líquidos Corporais / Urinálise / Eletroforese Capilar / Membranas Artificiais Limite: Humans Idioma: En Revista: J Chromatogr A Ano de publicação: 2019 Tipo de documento: Article