Your browser doesn't support javascript.
loading
The influence of thyroid nodule size on the diagnostic efficacy and accuracy of ultrasound guided fine-needle aspiration cytology.
Aydogan, Berna Imge; Sahin, Mustafa; Ceyhan, Koray; Deniz, Olgun; Demir, Özgür; Emral, Rifat; Tonyukuk Gedik, Vedia; Uysal, Ali Riza; Çorapçioglu, Demet.
Afiliação
  • Aydogan BI; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Sahin M; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Ceyhan K; Department of Cytology, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Deniz O; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Demir Ö; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Emral R; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Tonyukuk Gedik V; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Uysal AR; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
  • Çorapçioglu D; Department of Endocrinology and Metabolism, Ankara University Faculty of Medicine, Ankara, Turkey.
Diagn Cytopathol ; 47(7): 682-687, 2019 Jul.
Article em En | MEDLINE | ID: mdl-30861335
ABSTRACT

BACKGROUND:

Diagnostic accuracy of fine-needle aspiration cytology (FNAC) in large and subcentimeter nodules is still debated. We aimed to evaluate the impact of nodule size on efficacy of the ultrasound-guided FNAC.

METHODS:

B-mode grayscale ultrasound (US), US-guided FNAC according to Bethesda system and histopathological data of 514 nodules from 371 patients, who underwent thyroidectomy were examined retrospectively. Nodules were grouped by maximal diameter; group A nodules were smaller than 10 mm (n = 59), group B nodules were between 10 and 29 mm (n = 218), and group C nodules were 30 mm or greater (n = 130).

RESULTS:

Sensitivity, specificity, and accuracy of FNAC was 92.0%, 100%, and 95.1% in group A, 80.7%, 99.1%, and %92.9 in group B, 70.0%, 98.9%, and 95.8% in group C nodules, respectively. The prevalence of papillary thyroid cancer (PTC) and incidental PTC were 44.2% (n = 164) and 6.4% (n = 24), respectively. Malignancy rate was more frequent in group A when compared to groups B and C (P < 0.01). Nodule size was positively associated with follicular cancer risk (P = 0.009). The thyroid stimulating hormone level was positively associated with malignancy (P = 0.02) and optimal cut-off value was 0.96 mIU/L. False-negative rate was 8.0%, 19.3%, and 30.0% in groups A, B, and C nodules, respectively.

CONCLUSIONS:

Although the malignancy rate was low in nodules ≥30 mm, diagnostic surgery for large nodules should be considered because of decreased reliability of FNAC, ineffectiveness of clinical and sonographic criteria. False-negative rate was relatively low and malignancy rate was high in subcentimeter nodules, supporting the accuracy of FNAC.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nódulo da Glândula Tireoide / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Cytopathol Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nódulo da Glândula Tireoide / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Cytopathol Ano de publicação: 2019 Tipo de documento: Article