Your browser doesn't support javascript.
loading
A universal ultrasound diagnostic system developed to support urology and coloproctological applications.
Kim, Jeong Seok; Lee, Jong Gun; Choi, Jae Hyeok; Han, Bong Hyo; Yoon, Se Leang; Jung, Ho; Song, Tai Kyong; Lee, Jae Young.
Afiliação
  • Kim JS; Department of Research and Development, GE Ultrasound Korea, Seongnam, Gyeonggi Korea.
  • Lee JG; Department of Research and Development, GE Ultrasound Korea, Seongnam, Gyeonggi Korea.
  • Choi JH; Department of Research and Development, GE Ultrasound Korea, Seongnam, Gyeonggi Korea.
  • Han BH; Department of Research and Development, GE Ultrasound Korea, Seongnam, Gyeonggi Korea.
  • Yoon SL; Department of Research and Development, GE Ultrasound Korea, Seongnam, Gyeonggi Korea.
  • Jung H; Department of Research and Development, HumanScan, Ansan, Gyeonggi Korea.
  • Song TK; 3Department of Electronic Engineering, Sogang University, Seoul, Korea.
  • Lee JY; 4Department of Radiology and Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea.
Biomed Eng Lett ; 9(1): 119-125, 2019 Feb.
Article em En | MEDLINE | ID: mdl-30956885
In this study, we sought to describe a novel imaging apparatus that is lightweight, inexpensive, and highly effective for use in colorectal diagnostic and treatment settings. Typical probes for use in colorectal ultrasonic imaging applications are developed for surgeons to diagnose and stage rectal tumors and image the rectum and anus. Here we outline a new technique and use it for colorectal imaging in an animal. This technique involves use of an ultrasound array module positioned along the axis of rotation such that improved rotation is possible. This module is in the shape of a linear rod with a rotary linear component that allows for emission of focused ultrasonic echo signals from a linear section of the probe. The usability of the transducer and rectal image quality are satisfactory in a porcine model with the technique proposed here, axial/lateral resolution as 0.96/2.24 mm with 6 dB applied through the contour map using the point spread function. When compared to currently available methods, this technique provides superior diagnostic 3D volumetric image quality with reduced acquisition time. Given this, the ultrasound device proposed here may prove a viable and preferable method to those currently available for urology and colorectal imaging applications.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biomed Eng Lett Ano de publicação: 2019 Tipo de documento: Article