REVERSE SUTURE TECHNIQUE FOR INTRAOCULAR LENS REFIXATION.
Patel, Shriji N; Snyder, Laura L.
Afiliação
  • Patel SN; Department of Ophthalmology, Vanderbilt University Medical Center, Nashville, Tennessee; and.
  • Snyder LL; North Carolina Retina Associates, Raleigh, North Carolina.
Retin Cases Brief Rep ; 15(5): 625-627, 2021 Sep 01.
Article em En | MEDLINE | ID: mdl-30964779
ABSTRACT

PURPOSE:

To describe a novel reverse suture approach to safely and securely refixate dislocated intraocular lenses (IOLs).

METHODS:

We describe two cases herein where we use a reverse suture technique to refixate dislocated IOLs. By reversing the needle-holder grasp on a Gore-Tex suture needle, we can safely insert the base of the needle through the pars plana. This allows for looping of the suture around the haptic of subluxated or dislocated IOL. We use the technique in a case with a subluxed plate haptic IOL and a subluxed three-piece IOL with an encircling capsular tension ring.

RESULTS:

The reverse suture technique allows for safe and effective looping of a subluxed IOL haptic or capsular tension ring. This technique can be performed without an assistant and prevents excessive manipulation and unnecessary explantation of dislocated IOL.

CONCLUSION:

The reverse suture technique is a safe, effective, and easily reproducible maneuver to refixate dislocated IOLs.