[The study of exposure levels of dioxin-like compounds in cord blood of newborns in an e-waste dismantling area in Guangdong Province].
Zhonghua Yu Fang Yi Xue Za Zhi
; 53(4): 365-370, 2019 Apr 06.
Article
em Zh
| MEDLINE
| ID: mdl-30982269
Objective: To study the pollution status of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCB), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in cord blood of newborns in an e-waste dismantling area of Guangdong Province. Methods: We recruited 20 eligible mothers and newborns who could meet the inclusion criteria in local hospitals of Guiyu in 2007. The inclusion criteria included directly engaged in dismantling e-waste during pregnancy and within 1 year before pregnancy; living in the e-waste dismantling workshops or the distance between living place and the e-waste dismantling areas was ≤200 m; the father of newborn was directly engaged in electronic waste dismantling for more than 1 year; the frequency of visiting the e-waste dismantling workshop during pregnancy was ≥3 times in a week. Questionnaires and physical examinations were performed on maternal and neonatal, and cord blood was collected from newborns to detect PCDD/Fs, PCB and PBDE. The concentration level of organic pollutants was corrected by the blood lipid content, and the total toxicity equivalent was calculated. The correlation between three compounds was analyzed by Spearman correlation. Results: The mothers of the 20 newborns were (23.45±3.27) years old and lived for more than 5 years. The number of one parent engaged in e-waste dismantling, the mother or father smoking, and parent engaged in e-waste dismantling work were 3, 13, 15 and 19, respectively. The weight of newborns ranged from 2.5 to 3.6 kilogram and the Apgar score was 10 points. No adverse birth outcomes such as preterm birth, malformation or stillbirth were found. The median (maximum, minimum) concentration of PCBs, PCDD/Fs and PBDEs in cord blood were 263.22 (328.29, 244.19), 38.42 (147.49, 12.68), 39.33 (265.11, 14.81) pg/g lipid, respectively. The median (maximum, minimum) of toxic equivalence concentrations of PCDD/Fs and PCB were 3.94 (9.24, 2.69) and 15.95 (26.64, 9.28) pg TEQ/g lipid. PBDE, the proportion of PBDE, PCB and PCDD/Fs in cord blood was 50.41%, 49.25% and 0.34%, respectively. PCBs and PBDEs were positively correlated (r=0.733, P=0.039). Conclusion: The high concentrations of PCDD/Fs, PCB, and PBDE were detected in the e-waste dismantling area. It is recommended that the risk of such substances on the health of local people should be assessed in a timely manner.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Contexto em Saúde:
12_ODS3_hazardous_contamination
Base de dados:
MEDLINE
Assunto principal:
Bifenilos Policlorados
/
Dioxinas
/
Exposição Ambiental
/
Poluentes Ambientais
/
Sangue Fetal
/
Reciclagem
/
Resíduo Eletrônico
/
Dibenzodioxinas Policloradas
Limite:
Adult
/
Female
/
Humans
/
Newborn
/
Pregnancy
Idioma:
Zh
Revista:
Zhonghua Yu Fang Yi Xue Za Zhi
Ano de publicação:
2019
Tipo de documento:
Article