Your browser doesn't support javascript.
loading
The Responsiveness of Triaxial Accelerometer Measurement of Gait Ataxia Is Higher than That of the Scale for the Assessment and Rating of Ataxia in the Early Stages of Spinocerebellar Degeneration.
Shirai, Shinichi; Yabe, Ichiro; Takahashi-Iwata, Ikuko; Matsushima, Masaaki; Ito, Yoichi M; Takakusaki, Kaoru; Sasaki, Hidenao.
Afiliação
  • Shirai S; Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15W7, Kita-ku, Sapporo, 060-8638, Japan.
  • Yabe I; Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15W7, Kita-ku, Sapporo, 060-8638, Japan.
  • Takahashi-Iwata I; Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15W7, Kita-ku, Sapporo, 060-8638, Japan.
  • Matsushima M; Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15W7, Kita-ku, Sapporo, 060-8638, Japan.
  • Ito YM; Department of Biostatistics, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
  • Takakusaki K; The Research Center for Brain Function and Medical Engineering, Asahikawa Medical University, Asahikawa, Japan.
  • Sasaki H; Department of Neurology, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15W7, Kita-ku, Sapporo, 060-8638, Japan. h-isasak@med.hokudai.ac.jp.
Cerebellum ; 18(4): 721-730, 2019 Aug.
Article em En | MEDLINE | ID: mdl-30993540
We reported previously that the average medial-lateral gait amplitude while walking on a straight path determined using triaxial accelerometers fixed on the middle of the upper back may be a quantitative and concise indicator for the severity of cerebellar ataxia. Considering that gait ataxia is a typical initial symptom in a variety of spinocerebellar degeneration (SCD), we aimed to develop quantitative biomarkers for cerebellar ataxia as metric variables. We used triaxial accelerometers to analyze gait parameters in 14 patients with SCD at 3 points over 3 years (at baseline, 1.5 years and 3 years). Analysis of covariance (ANCOVA) models adjusted for the baseline scores were used to estimate sample sizes. The mean medial-lateral amplitude (ML) gained by a triaxial accelerometer fixed on upper back could detect the each 1.5-year change. In the 14 patients, the mean ML(m) was 0.032 ± 0.007(SD) at entry, 0.037 ± 0.008 after 1.5-year follow, and 0.042 ± 0.020 after 3-year follow. In contrast, SARA gait scores were 2.9, 2.9, and 3.0, respectively. The responsiveness of the quantitative evaluation of gait ataxia by triaxial accelerometers is higher than that of the SARA within a 1.5-year follow-up period. Gait analysis by triaxial accelerometers will be complementary to the evaluation of scales like SARA in the assessment of clinical severity of SCD patients in early stage.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Degenerações Espinocerebelares / Marcha Atáxica / Acelerometria Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cerebellum Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Degenerações Espinocerebelares / Marcha Atáxica / Acelerometria Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Cerebellum Ano de publicação: 2019 Tipo de documento: Article