Your browser doesn't support javascript.
loading
The influence of temperature during water-quench rapid heat treatment on the microstructure, mechanical properties and biocompatibility of Ti6Al4V ELI alloy.
Chafino, J A; Yamanaka, K; Mercier, F; Rivory, P; Balvay, S; Hartmann, D J; Chiba, A; Fabregue, D.
Afiliação
  • Chafino JA; Univ Lyon, INSA-Lyon, MATEIS, UMR CNRS 5510, 20 Avenue Einstein, 69621, Villeurbanne, France. Electronic address: ja.chafino@gmail.com.
  • Yamanaka K; Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, 980-8577, Japan.
  • Mercier F; Univ Lyon, INSA-Lyon, MATEIS, UMR CNRS 5510, 20 Avenue Einstein, 69621, Villeurbanne, France.
  • Rivory P; Univ Lyon, Universite Claude Bernard Lyon1, MATEIS, UMR CNRS 5510, 8 avenue Rockefeller, 69373, Lyon, France.
  • Balvay S; Univ Lyon, Universite Claude Bernard Lyon1, MATEIS, UMR CNRS 5510, 8 avenue Rockefeller, 69373, Lyon, France.
  • Hartmann DJ; Univ Lyon, Universite Claude Bernard Lyon1, MATEIS, UMR CNRS 5510, 8 avenue Rockefeller, 69373, Lyon, France.
  • Chiba A; Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, 980-8577, Japan.
  • Fabregue D; Univ Lyon, INSA-Lyon, MATEIS, UMR CNRS 5510, 20 Avenue Einstein, 69621, Villeurbanne, France. Electronic address: damien.fabregue@insa-lyon.fr.
J Mech Behav Biomed Mater ; 96: 144-151, 2019 08.
Article em En | MEDLINE | ID: mdl-31035065
ABSTRACT
This study investigates the influence of a rapid heat treatment followed by water-quenching on the mechanical properties of Ti6Al4V ELI alloy to improve its strength for use in implants. Prior to the experiment, a dilatometry test was performed to understand the progressive α-to ß-phase transformation taking place during heating. The results were then used to carry out heat treatments. Microstructure was analysed using SEM, EBSD, EDX and XRD techniques. Vickers micro-hardness, tensile and high cycle rotating bending tests were used to analyse the influence of the $\alpha'$-phase fraction on the strength of the studied alloy. Results show that this process can provide a Ti6Al4V ELI alloy with a better Yield Strength (YS)/uniform deformation (εu) ratio and improved high cycle fatigue strength than those observed in the current microstructure used in medical implants. Lastly, cytotoxicity tests were performed on two types of human cells, namely MG63 osteoblast-like cells and fibroblasts. The results reveal the non-toxicity of the heat-treated Ti6Al4V ELI alloy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Teste de Materiais / Água / Ligas / Fenômenos Mecânicos / Temperatura Alta Limite: Humans Idioma: En Revista: J Mech Behav Biomed Mater Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Teste de Materiais / Água / Ligas / Fenômenos Mecânicos / Temperatura Alta Limite: Humans Idioma: En Revista: J Mech Behav Biomed Mater Ano de publicação: 2019 Tipo de documento: Article