Your browser doesn't support javascript.
loading
Nanoparticle-Based LDI-MS Immunoassay for the Multiple Diagnosis of Viral Infections.
Chu, Han-Wei; Lai, Chao-Sung; Ko, Jo-Yun; Harroun, Scott G; Chuang, Chiao-I; Wang, Robert Y L; Unnikrishnan, Binesh; Huang, Chih-Ching.
Afiliação
  • Chu HW; Department of Bioscience and Biotechnology , National Taiwan Ocean University , Keelung 20224 , Taiwan.
  • Lai CS; Biomedical Engineering Research Center, Department of Electronic Engineering , Chang Gung University , Taoyuan 33302 , Taiwan.
  • Ko JY; Department of Nephrology , Chang Gung Memorial Hospital , Linkou, New Taipei 33305 , Taiwan.
  • Harroun SG; Department of Materials Engineering , Ming Chi University of Technology , New Taipei City 24301 , Taiwan.
  • Chuang CI; Department of Bioscience and Biotechnology , National Taiwan Ocean University , Keelung 20224 , Taiwan.
  • Wang RYL; Department of Chemistry , Université de Montréal , Montréal , Québec H3C 3J7 , Canada.
  • Unnikrishnan B; Department of Bioscience and Biotechnology , National Taiwan Ocean University , Keelung 20224 , Taiwan.
  • Huang CC; Department of Biomedical Sciences, College of Medicine , Chang Gung University , Taoyuan 33302 , Taiwan.
ACS Sens ; 4(6): 1543-1551, 2019 06 28.
Article em En | MEDLINE | ID: mdl-31066548
Many serious public health emergencies around the globe are caused by viral epidemics. Thus, developing a reliable method for viral screening is in high demand. Multiplex assays for simultaneous detection and fast screening of high-risk pathogens are especially needed. This study employs metal nanoparticles to generate specific mass spectral signals for different RNA viruses, which enables simultaneous detection of whole viruses by laser desorption/ionization mass spectrometry (LDI-MS). We developed a nanoparticle-based sandwich immunosorbent assay as a sensing platform for the detection of viruses and viral nonstructural protein by LDI-MS. Cellulose acetate membrane (CAM) serves as the substrate for the fabrication of the sandwich immunosorbent assay with the advantages of clean mass spectra and high enrichment of analytes. Antibody-modified metal nanoparticles (Ab-MNPs; M = Au or Ag) act as metallic biocodes for the LDI-MS detection. The signal amplification readout for the virus is through the pulsed laser-induced formation of metal cluster ions ([M n]+; n = 1-3) from the Ab-MNPs which specifically bind on the CAM. Our sensing system is effective for the detection of intact viruses [Enterovirus 71 (EV71) and Japanese encephalitis virus (JEV)], nonstructural protein 1 (NS1) of Zika virus (ZIKV), EV71-spiked human serum samples, and the simultaneous detection of EV71 and ZIKV. Our probe efficiently detects EV71 in real clinical serum samples with >95% agreement with RT-qPCR results. This high-throughput LDI-MS viral detection system is simple, reliable, and high-throughput. We believe this platform has the potential to be employed for the routine screening of patients with viral infections.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vírus de RNA / Espectrometria de Massas / Imunoensaio / Infecções por Flavivirus / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Limite: Adult / Animals / Humans / Male Idioma: En Revista: ACS Sens Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vírus de RNA / Espectrometria de Massas / Imunoensaio / Infecções por Flavivirus / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Limite: Adult / Animals / Humans / Male Idioma: En Revista: ACS Sens Ano de publicação: 2019 Tipo de documento: Article