Your browser doesn't support javascript.
loading
A Novel Bioelectronic Reporter System in Living Cells Tested with a Synthetic Biological Comparator.
Zeng, Ji; Banerjee, Areen; Kim, Jaewook; Deng, Yijie; Chapman, Tim W; Daniel, Ramez; Sarpeshkar, Rahul.
Afiliação
  • Zeng J; Thayer School of Engineering, Dartmouth, Hanover, New Hampshire, 03755, USA.
  • Banerjee A; Thayer School of Engineering, Dartmouth, Hanover, New Hampshire, 03755, USA.
  • Kim J; Thayer School of Engineering, Dartmouth, Hanover, New Hampshire, 03755, USA.
  • Deng Y; Thayer School of Engineering, Dartmouth, Hanover, New Hampshire, 03755, USA.
  • Chapman TW; Molecular and Cell Biology, Dartmouth, Hanover, New Hampshire, 03755, USA.
  • Daniel R; Technion - Israel Institute of Technology, Haifa, 3200003, Israel.
  • Sarpeshkar R; Departments of Engineering, Microbiology & Immunology, Physics, and Molecular and Systems Biology, Dartmouth, Hanover, New Hampshire, 03755, USA. rahul.sarpeshkar@dartmouth.edu.
Sci Rep ; 9(1): 7275, 2019 05 13.
Article em En | MEDLINE | ID: mdl-31086248
As the fields of biotechnology and synthetic biology expand, cheap and sensitive tools are needed to measure increasingly complicated genetic circuits. In order to bypass some drawbacks of optical fluorescent reporting systems, we have designed and created a co-culture microbial fuel cell (MFC) system for electronic reporting. This system leverages the syntrophic growth of Escheriachia. coli (E. coli) and an electrogenic bacterium Shewanella oneidensis MR-1 (S. oneidensis). The fermentative products of E. coli provide a carbon and electron source for S. oneidensis MR-1, which then reports on such activity electrically at the anode of the MFC. To further test the capability of electrical reporting of complicated synthetic circuits, a novel synthetic biological comparator was designed and tested with both fluorescent and electrical reporting systems. The results suggest that the electrical reporting system is a good alternative to commonly used optical fluorescent reporter systems since it is a non-toxic reporting system with a much wider dynamic range.
Assuntos

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Assunto principal: Fontes de Energia Bioelétrica Idioma: En Revista: Sci Rep Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Assunto principal: Fontes de Energia Bioelétrica Idioma: En Revista: Sci Rep Ano de publicação: 2019 Tipo de documento: Article