Your browser doesn't support javascript.
loading
Scapholunate Ligament Internal Brace 360 Tenodesis (SLITT) Procedure: A Biomechanical Study.
Kakar, Sanjeev; Greene, Ryan M; Denbeigh, Janet; Van Wijnen, Andre.
Afiliação
  • Kakar S; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Greene RM; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Denbeigh J; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Van Wijnen A; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
J Wrist Surg ; 8(3): 250-254, 2019 Jun.
Article em En | MEDLINE | ID: mdl-31192049
ABSTRACT
Background Twelve paired fresh frozen cadaveric wrists were randomized to a 360-degree tenodesis repair group or the 360-degree tenodesis repair with an internal brace (suture tape) construct. Case Description The specimens were preloaded to 5 N and subsequently biomechanically loaded to failure, at a rate of 0.1 mm/s on a jig that allowed for axial load. The maximum load and mode of failure were recorded. Load to failure in the 360 tenodesis group with internal brace was 283.47 ± 100.25 N, compared with the 360 tenodesis group only, whose yield strength was 143.61 ± 90.54 N. The mode of failure within the internal brace construct was either through knot slippage, graft disruption, or bone separation from strength testing construct. The 360 tenodesis group tended to fail via graft slippage or graft rupture. Literature Review The management of scapholunate instability can be a difficult problem to treat. Traditionally, many of the surgical reconstructions have focused upon dorsal ligament reconstruction with Kirschner (K) wire fixation. This results in prolonged immobilization of the wrist with varied outcomes, in part due to the multiaxial instability that may persist due to concomitant volar ligament disruption. To address this instability, surgical techniques have been devised that address both the volar and dorsal ligament injuries. Clinical Relevance Scapholunate reconstruction with a 360-degree tenodesis and internal brace augmentation (SLITT procedure) provided superior biomechanical stability than tenodesis alone.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Revista: J Wrist Surg Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Revista: J Wrist Surg Ano de publicação: 2019 Tipo de documento: Article