Your browser doesn't support javascript.
loading
Pathogenic heparin-induced thrombocytopenia and thrombosis (HIT) antibodies determined by rapid functional flow cytometry.
Cipok, Michal; Tomer, Aaron; Elalamy, Ismail; Kirgner, Ilya; Dror, Naama; Kay, Sigi; Deutsch, Varda R.
Afiliação
  • Cipok M; The Hematology Institute, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Tomer A; The Hematology Institute, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Elalamy I; Hematology and Thrombosis Center, Tenon University Hospital, INSERM UMRS 938, Sorbonne University, Paris, France.
  • Kirgner I; Department of Obstetrics and Gynecology, I.M. Sechenov First Moscow State Medical University, Moscow, Russia.
  • Dror N; The Hematology Institute, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Kay S; The Hematology Institute, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Deutsch VR; The Hematology Institute, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Eur J Haematol ; 103(3): 225-233, 2019 Sep.
Article em En | MEDLINE | ID: mdl-31206215
OBJECTIVES: Reliable diagnosis of heparin-induced thrombocytopenia and thrombosis (HIT) is mandatory for patient management, yet prompt determination of pathogenic antibodies remains an unmet clinical challenge. Common immunoassays carry inherent limitations and functional assays which detect antibody-mediated platelet activation are not usually readily available to routine laboratories, especially the serotonin release assay (SRA), being technically demanding, time consuming, and requires high level expertise. To overcome some of these limitations, we have developed a practical functional flow cytometric assay (FCA) for routine clinical use. METHODS: A simple FCA is described which avoids platelet manipulation, is highly specific and sensitive compared with SRA, and provides rapid results. RESULTS: Of the 650 consecutive samples, from HIT-suspected patients, 99 (15.3%) were positive by the PaGIA Heparin/PF4 immunoassay and 31 (4.8%) by FCA. Average platelet activation was 11-fold higher in PaGIA+/FCA+ vs PaGIA-/FCA- samples. Of 21 SRA-positive samples, 19 were FCA-positive (relative sensitivity 90.5%), and of 42 SRA-negative samples, 40 were FCA-negative (relative specificity 95.2%). The FCA showed significantly higher correlation with the clinical presentation of HIT (4Ts score) performed on 182 patients, compared with PaGIA Heparin/PF4 (ROC-plot analysis, AUC 0.93 vs 0.63, P < 0.001). At a 92% sensitivity, the assay specificity was 96%. CONCLUSIONS: The present FCA is practical for routine testing, providing prompt reliable results for initial diagnosis and confirmation, to effectively assist in HIT patient management.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombocitopenia / Trombose / Plaquetas / Heparina / Citometria de Fluxo Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Haematol Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombocitopenia / Trombose / Plaquetas / Heparina / Citometria de Fluxo Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Haematol Ano de publicação: 2019 Tipo de documento: Article