Your browser doesn't support javascript.
loading
A word of caution: diabolic behaviour of AndraStents®: inflation of supporting balloon leads to "diabolo"-misconfiguration of the stent.
Happel, Christoph M; Zunzunegui Martínez, Jose L; Del Cerro, María Jesús; Schranz, Dietmar; Khalil, Markus; Ballesteros, Fernando; Pardeiro, César Abelleira; Bertram, Harald; Beerbaum, Philipp; Haas, Nikolaus A.
Afiliação
  • Happel CM; Pediatric Cardiology & Intensive Care Medicine, Department for Pediatric Cardiology and Intensive Care Medicine, Hannover Medical School, Hannover, Lower Saxony, Germany.
  • Zunzunegui Martínez JL; Unidad de Cardiología Infantil, Department for Pediatric Cardiology, Hospital Universitario Gregorio Marañón, Madrid, Madrid, Spain.
  • Del Cerro MJ; Servicio de Cardiología Infantil, Department for Pediatric Cardiology, Hospital Universitario Ramón y Cajal, Madrid, Spain.
  • Schranz D; Pediatric Heart Center Hesse, Department for Pediatric Cardiology, University Hospital Giessen and Marburg, Giessen, Hesse, Germany.
  • Khalil M; Pediatric Heart Center Hesse, Department for Pediatric Cardiology, University Hospital Giessen and Marburg, Giessen, Hesse, Germany.
  • Ballesteros F; Unidad de Cardiología Infantil, Department for Pediatric Cardiology, Hospital Universitario Gregorio Marañón, Madrid, Madrid, Spain.
  • Pardeiro CA; Servicio de Cardiología Infantil, Department for Pediatric Cardiology, Hospital Universitario Ramón y Cajal, Madrid, Spain.
  • Bertram H; Pediatric Cardiology & Intensive Care Medicine, Department for Pediatric Cardiology and Intensive Care Medicine, Hannover Medical School, Hannover, Lower Saxony, Germany.
  • Beerbaum P; Pediatric Cardiology & Intensive Care Medicine, Department for Pediatric Cardiology and Intensive Care Medicine, Hannover Medical School, Hannover, Lower Saxony, Germany.
  • Haas NA; Department for Pediatric Cardiology and Pediatric Intensive Care, Ludwig Maximilians University, Medical Hospital of the University of Munich, Campus Grosshadern, Munich, Bavaria, Germany.
Cardiol Young ; 29(7): 972-976, 2019 Jul.
Article em En | MEDLINE | ID: mdl-31218985

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Pulmonar / Falha de Prótese / Obstrução do Fluxo Ventricular Externo / Angioplastia Coronária com Balão / Stents / Implante de Prótese de Valva Cardíaca Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male Idioma: En Revista: Cardiol Young Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Pulmonar / Falha de Prótese / Obstrução do Fluxo Ventricular Externo / Angioplastia Coronária com Balão / Stents / Implante de Prótese de Valva Cardíaca Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male Idioma: En Revista: Cardiol Young Ano de publicação: 2019 Tipo de documento: Article