Your browser doesn't support javascript.
loading
Novel HILIC-ESI-MS method for urinary profiling of MSUD and methylmalonic aciduria biomarkers.
Mathew, Elizabeth Mary; Lewis, Leslie; Rao, Pragna; Nalini, K; Kamath, Asha; Moorkoth, Sudheer.
Afiliação
  • Mathew EM; Department of Pharmaceutical Quality Assurance, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
  • Lewis L; Department of Paediatrics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
  • Rao P; Department of Biochemistry, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
  • Nalini K; Department of Biochemistry, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
  • Kamath A; Department of Statistics, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
  • Moorkoth S; Department of Pharmaceutical Quality Assurance, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India.
J Chromatogr Sci ; 57(8): 715-723, 2019 Aug 16.
Article em En | MEDLINE | ID: mdl-31251316
ABSTRACT
Methyl malonic acid and branched-chain keto acids are important biomarkers for the diagnosis of cobalamin deficiencies and maple syrup urine disease. We report the development and validation of a HILIC-ESI-MS2 method for the quantification of these organic acids from neonatal urine. The samples were 100 times diluted and analyzed on a ZIC-HILIC column with 25-mM formic acid in water 25-mM formic acid in acetonitrile (4555) at a flow rate of 0.8 mL/min with a runtime of only 6 minutes. The method demonstrated a lower limit of detection of 10 ng/mL, Limit of Quantification (LOQ) of 50 ng/mL, linearity of r2 ≥ 0.990 and recoveries of 87-105% for all analytes. The intraday and interday precision CV's were <10% and 12%, respectively. Extensive stability studies demonstrated the analytes to be stable in stock and in matrix with a percent change within ±15%. The Bland-Altman analysis of the developed method with the gold standard GCMS method demonstrated a bias of 0.44, 0.11, 0.009 and -0.19 for methyl malonic acid, 3-methyl-2-oxovaleric acid, 2-hydroxy-3methylbutyric acid and 4-methyl-2-oxovaleric acid, respectively, proving the methods are comparable. The newly developed method involves no derivatization and has a simple sample preparation and a low runtime, enabling it to be easily automated with a high sample throughput in a cost-effective manner.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biomarcadores / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Erros Inatos do Metabolismo dos Aminoácidos / Doença da Urina de Xarope de Bordo Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biomarcadores / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray / Erros Inatos do Metabolismo dos Aminoácidos / Doença da Urina de Xarope de Bordo Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2019 Tipo de documento: Article