Development and Ex Vivo Validation of Novel Force-Sensing Neochordae for Measuring Chordae Tendineae Tension in the Mitral Valve Apparatus Using Optical Fibers With Embedded Bragg Gratings.
Paulsen, Michael J; Bae, Jung Hwa; Imbrie-Moore, Annabel M; Wang, Hanjay; Hironaka, Camille E; Farry, Justin M; Lucian, Haley; Thakore, Akshara D; Cutkosky, Mark R; Joseph Woo, Y.
Afiliação
  • Paulsen MJ; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305.
  • Bae JH; Department of Mechanical Engineering, Stanford University, Stanford, CA 94305.
  • Imbrie-Moore AM; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305; Department of Mechanical Engineering, Stanford University, Stanford, CA 94305.
  • Wang H; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305.
  • Hironaka CE; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305.
  • Farry JM; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305.
  • Lucian H; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305.
  • Thakore AD; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305.
  • Cutkosky MR; Department of Mechanical Engineering, Stanford University, Stanford, CA 94305.
  • Joseph Woo Y; Norman E. Shumway Professor and Chair Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305; Department of Bioengineering, Stanford University, Stanford, CA 94305.
J Biomech Eng ; 142(1)2020 01 01.
Article em En | MEDLINE | ID: mdl-31253992
ABSTRACT
Few technologies exist that can provide quantitative data on forces within the mitral valve apparatus. Marker-based strain measurements can be performed, but chordal geometry and restricted optical access are limitations. Foil-based strain sensors have been described and work well, but the sensor footprint limits the number of chordae that can be measured. We instead utilized fiber Bragg grating (FBG) sensors-optical strain gauges made of 125 µm diameter silica fibers-to overcome some limitations of previous methods of measuring chordae tendineae forces. Using FBG sensors, we created a force-sensing neochord (FSN) that mimics the natural shape and movement of native chordae. FBG sensors reflect a specific wavelength of light depending on the spatial period of gratings. When force is applied, the gratings move relative to one another, shifting the wavelength of reflected light. This shift is directly proportional to force applied. The FBG sensors were housed in a protective sheath fashioned from a 0.025 in. flat coil, and attached to the chordae using polytetrafluoroethylene suture. The function of the force-sensing neochordae was validated in a three-dimensional (3D)-printed left heart simulator, which demonstrated that FBG sensors provide highly sensitive force measurements of mitral valve chordae at a temporal resolution of 1000 Hz. As ventricular pressures increased, such as in hypertension, chordae forces also increased. Overall, FBG sensors are a viable, durable, and high-fidelity sensing technology that can be effectively used to measure mitral valve chordae forces and overcome some limitations of other such technologies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cordas Tendinosas Idioma: En Revista: J Biomech Eng Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cordas Tendinosas Idioma: En Revista: J Biomech Eng Ano de publicação: 2020 Tipo de documento: Article