Your browser doesn't support javascript.
loading
Different removal efficiency of disinfection-byproduct precursors between dichloroacetonitrile (DCAN) and dichloroacetamide (DCAcAm) by up-flow biological activated carbon (UBAC) process.
Chen, Han; Lin, Tao; Chen, Wei; Xu, Hang; Tao, Hui.
Afiliação
  • Chen H; Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, People's Republic of China.
  • Lin T; College of Environment, Hohai University, Nanjing, 210098, People's Republic of China.
  • Chen W; Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, People's Republic of China. hit_lintao@163.com.
  • Xu H; College of Environment, Hohai University, Nanjing, 210098, People's Republic of China. hit_lintao@163.com.
  • Tao H; Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, People's Republic of China.
Environ Sci Pollut Res Int ; 26(25): 25874-25882, 2019 Sep.
Article em En | MEDLINE | ID: mdl-31273652
ABSTRACT
Up-flow biological activated carbon (UBAC) filter has been widely used in waterworks due to its less hydraulic loss, stronger biodegradation ability, and the prevention of excessive biomass growth relative to down-flow BAC treatment. In this study, the different removal efficiency (DRE) of disinfection byproduct precursors between dichloroacetonitrile (DCAN) and dichloroacetamide (DCAcAm) was evaluated when UBAC filter was used as advanced treatment process. Results showed that the UBAC filter with approximately 36 months of usage time had a poor performance in the removal of DCAcAm formation potential (FP) (i.e. 9.3-19.1%) compared to DCAN FP (i.e., 22.5-34.1%). After chlorination of UBAC effluent, the hydrolysis of DCAN to form DCAcAm only partly contributed to the DRE variations of both DCAN FP and DCAcAm FP. Using the high-throughput sequencing technology and the redundancy analysis (RDA), the second dominant genus Bacillus in UBAC filter, which may transform precursors of DCAN into inorganic matters, could be another reason that led to the DRE in DCAN and DCAcAm FP. The formation and leakage of soluble microbial products (SMPs) was identified by excitation-emission matrix (EEM) peak intensities as well as variation of biological index (BIX). The SMPs released into UBAC effluent, favoring the formation of DCAcAm, also contributed to the precursors of both DCAN and DCAcAm, causing a poor removal performance in DCAcAm FP by UBAC filter.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Acetonitrilas / Carvão Vegetal / Desinfecção / Acetamidas Idioma: En Revista: Environ Sci Pollut Res Int Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Acetonitrilas / Carvão Vegetal / Desinfecção / Acetamidas Idioma: En Revista: Environ Sci Pollut Res Int Ano de publicação: 2019 Tipo de documento: Article