Your browser doesn't support javascript.
loading
Adaptation of diffusive gradients in thin films technique to sample organic pollutants in the environment: An overview of o-DGT passive samplers.
Guibal, Robin; Buzier, Rémy; Lissalde, Sophie; Guibaud, Gilles.
Afiliação
  • Guibal R; University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France. Electronic address: robin.guibal@unilim.fr.
  • Buzier R; University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France.
  • Lissalde S; University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France.
  • Guibaud G; University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France.
Sci Total Environ ; 693: 133537, 2019 Nov 25.
Article em En | MEDLINE | ID: mdl-31357036
The adaptation of the diffusive gradients in thin films technique (DGT) to sample organic pollutants in the environment, called o-DGT has been performed since 2011 for various types of organic compounds (e.g. pesticides, pharmaceuticals, hormones, endocrine disrupting chemicals, household and personal care products). To sample these different compounds, configuration of the samplers (mainly receiving phase and diffusive gel) has to be adapted. Up-to-date, sampling of 142 organic compounds by this passive sampler have been tested. This review provides the state-of-art of o-DGT passive sampler development, describing theory and modelling, calibration, configuration of the devices, and field applications. The most used configurations were agarose-XAD-18 and agarose-HLB configuration. o-DGT can be used to sample soils and most of natural waters (range of pH 4-9 and ionic strength 0.001-0.1 M). This review discusses current limitation of o-DGT in light of the feedback of DGT use to sample inorganic contaminants. It mainly concern the low sampling rates currently obtained by o-DGT compared to other passive samplers. This weakness could be compensated in the future with new sampler's design allowing an increase in exposure area.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Total Environ Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Total Environ Ano de publicação: 2019 Tipo de documento: Article