Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles.
Chen, Guoqian; Wu, Jiatao; Chen, Guocai; Lu, Yanyan; Ren, Wei; Xu, Wu; Xu, Xuemeng; Wu, Zugui; Guan, Yingxin; Zheng, Yi; Qiu, Bofan.
Afiliação
  • Chen G; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Wu J; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Chen G; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Lu Y; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Ren W; Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, Guangdong, China.
  • Xu W; Orthopedics Department, Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, Guangdong, China.
  • Xu X; Orthopedics Department, Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, Guangdong, China.
  • Wu Z; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Guan Y; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Zheng Y; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Qiu B; Fifth Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
PLoS One ; 14(7): e0220521, 2019.
Article em En | MEDLINE | ID: mdl-31365582
ABSTRACT
The reliability of MyotonPRO that can monitor the mechanical properties of tissues is still unclear. This study aimed to analyze the within-day inter-operator and between-day intra-operator reliability of MyotonPRO for assessing tone and stiffness of quadriceps femoris and patellar tendon at different knee angles. The tone and stiffness of healthy participants (15 males and 15 females, aged 24.7±1.6 years) in the supine and resting position were measured using the MyotonPRO device. The measurements were quantified at 0°, 30°, 60°, and 90° of knee flexion. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated and a Bland-Altman analysis was conducted to estimate reliability. The results indicated excellent inter-operator reliability (ICC > 0.78) and good to excellent intra-operator reliability (ICC > 0.41). The inter-operator SEM measurements ranged between 0.1-0.9 Hz and 3.8-37.9 N/m, and intra-operator SEM ranged between 0.5-1.3 Hz and 7.9-52.0 N/m. The inter-operator MDC ranged between 0.3-2.5 Hz and 10.5-105.1 N/m, and intra-operator SEM ranged between 1.1-3.3 Hz and 21.9-144.1 N/m. The agreement of inter-operator was better than that of intra-operator. The study concluded that MyotonPRO is a reliable device to detect the tone and stiffness of quadriceps femoris and patellar tendon.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Amplitude de Movimento Articular / Ligamento Patelar / Músculo Quadríceps / Técnicas de Imagem por Elasticidade / Articulação do Joelho / Tono Muscular Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: PLoS One Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Amplitude de Movimento Articular / Ligamento Patelar / Músculo Quadríceps / Técnicas de Imagem por Elasticidade / Articulação do Joelho / Tono Muscular Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: PLoS One Ano de publicação: 2019 Tipo de documento: Article