Your browser doesn't support javascript.
loading
Measurement of α-dicarbonyl compounds in human saliva by pre-column derivatization HPLC.
Wang, Xin-Jie; Zhang, Hong-Xia; Li, Heng; Zhu, Ai-Hua; Gao, Wen-Yun.
Afiliação
  • Wang XJ; National Engineering Research Center for Miniaturized Detection Systems and College of Life Sciences, Northwest University, Xi'an, Shaanxi, P.R. China.
  • Zhang HX; National Engineering Research Center for Miniaturized Detection Systems and College of Life Sciences, Northwest University, Xi'an, Shaanxi, P.R. China.
  • Li H; National Engineering Research Center for Miniaturized Detection Systems and College of Life Sciences, Northwest University, Xi'an, Shaanxi, P.R. China.
  • Zhu AH; The Shaanxi Key Laboratory of Chinese Medicine Research and Development, Xi'an, P.R. China.
  • Gao WY; National Engineering Research Center for Miniaturized Detection Systems and College of Life Sciences, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi 710069, P.R. China.
Clin Chem Lab Med ; 57(12): 1915-1922, 2019 Nov 26.
Article em En | MEDLINE | ID: mdl-31377732
ABSTRACT
Background α-Dicarbonyl compounds (α-DCs) have been detected in body fluids including plasma and urine and elevation of this sort of compounds in vivo has been associated with the development of many kinds of chronic diseases. However whether α-DCs are present in human saliva, and if their presence/absence can be related with various chronic diseases is yet to be determined. Methods In this study, a pre-column derivatization HPLC-UV method was developed to measure 3-deoxyglucosone (3-DG), glyoxal (GO), methylglyoxal (MGO), diacetyl (DA), and pentane-2,3-dione (PD) in human saliva employing 4-(2,3-dimethyl-6-quinoxalinyl)-1,2-benzenediamine (DQB) as a derivatizing reagent. The derivatization of the α-DCs is fast and the conditions are facile. The method was evaluated and the results show that it is suitable for the quantification of α-DCs in human saliva. Results In the measurements of these α-DCs in the saliva of 15 healthy subjects and 23 type 2 diabetes mellitus (T2DM) patients, we found that the concentrations of GO and MGO in the saliva of the diabetic patients were significantly higher than those in healthy subjects. As far as we know, this is the first time that salivary α-DC concentrations have been determined and associated with T2DM. Conclusions The developed method would be useful for the measurement of the salivary α-DC levels and the data acquired could be informative in the early screening for diabetes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aldeído Pirúvico / Desoxiglucose / Glioxal Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Chem Lab Med Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aldeído Pirúvico / Desoxiglucose / Glioxal Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Chem Lab Med Ano de publicação: 2019 Tipo de documento: Article