Your browser doesn't support javascript.
loading
Improving the imaging capability of an on-axis transmission Kikuchi detector.
Fanta, Alice Bastos S; Fuller, Adam; Alimadadi, Hossein; Todeschini, Matteo; Goran, Daniel; Burrows, Andrew.
Afiliação
  • Fanta ABS; DTU Nanolab, National Centre for Nano Fabrication and Characterization, Technical University of Denmark, Fysikvej 307, 2800 Kgs. Lyngby, Denmark. Electronic address: alice.fanta@cen.dtu.dk.
  • Fuller A; DTU Nanolab, National Centre for Nano Fabrication and Characterization, Technical University of Denmark, Fysikvej 307, 2800 Kgs. Lyngby, Denmark. Electronic address: adam.fuller@cen.dtu.dk.
  • Alimadadi H; DTU Nanolab, National Centre for Nano Fabrication and Characterization, Technical University of Denmark, Fysikvej 307, 2800 Kgs. Lyngby, Denmark; Danish Technological Institute, Kongsvang Alle 29, 8000 Aarhus C, Denmark. Electronic address: hoal@teknologisk.dk.
  • Todeschini M; DTU Nanolab, National Centre for Nano Fabrication and Characterization, Technical University of Denmark, Fysikvej 307, 2800 Kgs. Lyngby, Denmark; Blue Scientific Ltd., St. John's Innovation Centre, Cowley Road, Cambridge CB4 0WS, UK.
  • Goran D; Bruker Nano GmbH, Berlin, Germany. Electronic address: Daniel.Goran@bruker.com.
  • Burrows A; DTU Nanolab, National Centre for Nano Fabrication and Characterization, Technical University of Denmark, Fysikvej 307, 2800 Kgs. Lyngby, Denmark; ISS Group Services Ltd, Pellowe House, Francis Road, Withington, Manchester, Greater Manchester M20 4XP, UK.
Ultramicroscopy ; 206: 112812, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31382231
ABSTRACT
Transmission Kikuchi Diffraction (TKD) in the scanning electron microscope has been developing at a fast pace since its introduction less than a decade ago. The recently presented on-axis detector configuration, with its optimized geometry, has significantly increased the signal yield and facilitated the acquisition of STEM images in bright field (BF) and dark field (DF) mode, in addition to the automated orientation mapping of nanocrystalline electron transparent samples. However, the physical position of the integrated imaging system, located outside the detector screen, requires its movement in order to combine high resolution STEM images with high resolution orientation measurements. The difference between the two positions makes it impossible to acquire optimal signals simultaneously, leading to challenges when investigating site-specific nanocrystalline microstructures. To eliminate this drawback, a new imaging capability was added at the centre of the on-axis TKD detector, thus enabling acquisition of optimal quality BF images and orientation maps without detector movement. The advantages brought about by this new configuration are presented and the associated limitations are discussed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultramicroscopy Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ultramicroscopy Ano de publicação: 2019 Tipo de documento: Article