Your browser doesn't support javascript.
loading
Comparison of clinical performance of i-gelⓇ and Baska MaskⓇ during laparoscopic cholecystectomy.
Choi, So Ron; Lee, Tae Young; Kim, Sung Wan; Park, Sang Yoong; Chung, Chan Jong; Kim, Jeong Ho.
Afiliação
  • Choi SR; Department of Anesthesiology and Pain Medicine, Dong-A University College of Medicine, Busan, Korea.
  • Lee TY; Department of Anesthesiology and Pain Medicine, Dong-A University College of Medicine, Busan, Korea.
  • Kim SW; Department of Anesthesiology and Pain Medicine, Dong-A University College of Medicine, Busan, Korea.
  • Park SY; Department of Anesthesiology and Pain Medicine, Dong-A University College of Medicine, Busan, Korea.
  • Chung CJ; Department of Anesthesiology and Pain Medicine, Dong-A University College of Medicine, Busan, Korea.
  • Kim JH; Department of Anesthesiology and Pain Medicine, Dong-A University College of Medicine, Busan, Korea.
Korean J Anesthesiol ; 72(6): 576-582, 2019 12.
Article em En | MEDLINE | ID: mdl-31426623
BACKGROUND: The supraglottic airway device is an appropriate alternative to tracheal intubation in laparoscopic surgery. We compared the Baska MaskⓇ with i-gelⓇ by measuring the oropharyngeal leak pressure (OLP) and hemodynamic and respiratory parameters during laparoscopic cholecystectomy. METHODS: A total of 97 patients were randomly allocated to either i-gel group (n = 49) or Baska Mask group (n = 48). Insertion time, number of insertion attempts, fiber-optic view of the glottis, and OLP were recorded. Heart rate, mean arterial pressure, peak airway pressure (PAP), lung compliance, and perioperative complications were assessed before, during, and after pneumoperitoneum. RESULTS: There were no significant differences between the two groups regarding demographic data, insertion time, fiber-optic view of the glottis, and the use of airway manipulation. The OLP was higher in the Baska Mask group than in the i-gel group (29.6 ± 6.8 cmH2O and 26.7 ± 4.5 cmH2O, respectively; P = 0.014). Heart rate, mean arterial pressure, PAP, and lung compliance were not significantly different between the groups. The incidence of perioperative complications was small and not statistically significant. CONCLUSIONS: Both the i-gel and Baska Mask provided a satisfactory airway during laparoscopic cholecystectomy. Compared with the i-gel, the Baska Mask demonstrated a higher OLP.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas / Colecistectomia Laparoscópica Tipo de estudo: Clinical_trials Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Korean J Anesthesiol Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas / Colecistectomia Laparoscópica Tipo de estudo: Clinical_trials Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Korean J Anesthesiol Ano de publicação: 2019 Tipo de documento: Article