Your browser doesn't support javascript.
loading
Development and validation of LC-MS/MS method for determination of DNDI-VL-2098 in mouse, rat, dog and hamster blood.
Patel, Bhavesh D; Uppal, Ritika; Pulakundam, Nageswararao; Patel, Jignesh P; Ramanathan, Vikram; Ameta, Rakshit; Launay, Delphine; Braillard, Stéphanie.
Afiliação
  • Patel BD; Drug Metabolism Pharmacokinetics & Bioanalysis, Eurofins Advinus Ltd, 21 & 22, Phase II, Peenya Industrial Area, Bengaluru 560058, India.
  • Uppal R; Department of Chemistry, PAHER University, Udaipur 313003, Rajasthan, India.
  • Pulakundam N; Drug Metabolism Pharmacokinetics & Bioanalysis, Eurofins Advinus Ltd, 21 & 22, Phase II, Peenya Industrial Area, Bengaluru 560058, India.
  • Patel JP; Drug Metabolism Pharmacokinetics & Bioanalysis, Eurofins Advinus Ltd, 21 & 22, Phase II, Peenya Industrial Area, Bengaluru 560058, India.
  • Ramanathan V; Drug Metabolism Pharmacokinetics & Bioanalysis, Eurofins Advinus Ltd, 21 & 22, Phase II, Peenya Industrial Area, Bengaluru 560058, India.
  • Ameta R; Drug Metabolism Pharmacokinetics & Bioanalysis, Eurofins Advinus Ltd, 21 & 22, Phase II, Peenya Industrial Area, Bengaluru 560058, India.
  • Launay D; Current address: Sun Pharma Advanced Research Company Ltd, Vadodara 390020, Gujarat, India.
  • Braillard S; Department of Chemistry, PAHER University, Udaipur 313003, Rajasthan, India.
Bioanalysis ; 11(15): 1419-1435, 2019 Aug.
Article em En | MEDLINE | ID: mdl-31490107
ABSTRACT

Aim:

To develop a bioanalytical method to support pharmacokinetic evaluation of DNDI-VL-2098 in mouse, rat, dog and hamster following oral administration. Results &

methodology:

A robust LC-MS/MS bioanalytical method was developed to quantify DNDI-VL-2098. DNDI-VL-2098 showed time-dependent recovery loss in acetonitrile precipitated plasma in all species. Acid-lysed whole blood was identified as a matrix in which recovery was stable over time. A two-step extraction procedure was used, with protein precipitation followed by liquid-liquid extraction with methyl tert-butyl ether. The assay was validated in the dynamic range of 5-5000 ng/ml for mouse, rat and dog blood, and a fit-for-purpose method was developed for hamster.

Conclusion:

A specific LC-MS/MS assay for DNDI-VL-2098 was developed and validated in hemolyzed blood.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxazóis / Análise Química do Sangue / Cromatografia Líquida / Espectrometria de Massas em Tandem / Nitroimidazóis Limite: Animals Idioma: En Revista: Bioanalysis Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxazóis / Análise Química do Sangue / Cromatografia Líquida / Espectrometria de Massas em Tandem / Nitroimidazóis Limite: Animals Idioma: En Revista: Bioanalysis Ano de publicação: 2019 Tipo de documento: Article