Your browser doesn't support javascript.
loading
Phantom validation of quantitative susceptibility and dynamic contrast-enhanced permeability MR sequences across instruments and sites.
Hobson, Nicholas; Polster, Sean P; Cao, Ying; Flemming, Kelly; Shu, Yunhong; Huston, John; Gerrard, Chandra Y; Selwyn, Reed; Mabray, Marc; Zafar, Atif; Girard, Romuald; Carrión-Penagos, Julián; Chen, Yu Fen; Parrish, Todd; Zhou, Xiaohong Joe; Koenig, James I; Shenkar, Robert; Stadnik, Agnieszka; Koskimäki, Janne; Dimov, Alexey; Turley, Dallas; Carroll, Timothy; Awad, Issam A.
Afiliação
  • Hobson N; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Polster SP; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Cao Y; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Flemming K; Department of Neurology, Mayo Clinic, Rochester, Minnesota, USA.
  • Shu Y; Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
  • Huston J; Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
  • Gerrard CY; Department of Radiology, University of New Mexico, Albuquerque, New Mexico, USA.
  • Selwyn R; Department of Radiology, University of New Mexico, Albuquerque, New Mexico, USA.
  • Mabray M; Department of Radiology, University of New Mexico, Albuquerque, New Mexico, USA.
  • Zafar A; Department of Neurology, University of New Mexico, Albuquerque, New Mexico, USA.
  • Girard R; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Carrión-Penagos J; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Chen YF; Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA.
  • Parrish T; Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA.
  • Zhou XJ; Center for MR Research and Department of Radiology, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Koenig JI; National Institute of Neurological Disorders and Stroke, Bethesda, Maryland, USA.
  • Shenkar R; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Stadnik A; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Koskimäki J; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Dimov A; Department of Diagnostic Radiology, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Turley D; Department of Diagnostic Radiology, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Carroll T; Department of Diagnostic Radiology, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
  • Awad IA; Neurovascular Surgery Program, Section of Neurosurgery, Department of Surgery, University of Chicago Medicine and Biological Sciences, Chicago, Illinois, USA.
J Magn Reson Imaging ; 51(4): 1192-1199, 2020 04.
Article em En | MEDLINE | ID: mdl-31515878
ABSTRACT

BACKGROUND:

Quantitative susceptibility mapping (QSM) and dynamic contrast-enhanced quantitative permeability (DCEQP) on magnetic resonance (MR) have been shown to correlate with neurovascular disease progression as markers of vascular leakage and hemosiderin deposition. Applying these techniques as monitoring biomarkers in clinical trials will be necessary; however, their validation across multiple MR platforms and institutions has not been rigorously verified.

PURPOSE:

To validate quantitative measurement of MR biomarkers on multiple instruments at different institutions. STUDY TYPE Phantom validation between platforms and institutions. PHANTOM MODEL T1 /susceptibility phantom, two-compartment dynamic flow phantom. FIELD STRENGTH/SEQUENCE 3T/QSM, T1 mapping, dynamic 2D SPGR. ASSESSMENT Philips Ingenia, Siemens Prisma, and Siemens Skyra at three different institutions were assessed. A QSM phantom with concentrations of gadolinium, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8 ppm was assayed. DCEQP was assessed by measuring a MultiHance bolus as the consistency of the width ratio of the curves at the input and outputs over a range of flow ratios between outputs. STATISTICAL TESTS Each biomarker was assessed by measures of accuracy (Pearson correlation), precision (paired t-test between repeated measurements), and reproducibility (analysis of covariance [ANCOVA] between instruments).

RESULTS:

QSM accuracy of r2 > 0.997 on all three platforms was measured. Precision (P = 0.66 Achieva, P = 0.76 Prisma, P = 0.69 Skyra) and reproducibility (P = 0.89) were good. T1 mapping of accuracy was r2 > 0.98. No significant difference between width ratio regression slopes at site 2 (P = 0.669) or site 3 (P = 0.305), and no significant difference between width ratio regression slopes between sites was detected by ANCOVA (P = 0.48). DATA

CONCLUSION:

The phantom performed as expected and determined that MR measures of QSM and DCEQP are accurate and consistent across repeated measurements and between platforms. LEVEL OF EVIDENCE 1 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2020;511192-1199.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies Idioma: En Revista: J Magn Reson Imaging Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies Idioma: En Revista: J Magn Reson Imaging Ano de publicação: 2020 Tipo de documento: Article