Your browser doesn't support javascript.
loading
NanoSIMS Imaging of D/H Ratios on FIB Sections.
Lévy, Dan; Aléon, Jérôme; Aléon-Toppani, Alice; Troadec, David; Duhamel, Rémi; Gonzalez-Cano, Adriana; Bureau, Hélène; Khodja, Hicham.
Afiliação
  • Lévy D; Institut de Minéralogie de Physique des Matériaux, de Minéralogie et de Cosmochimie (IMPMC), Museum National d'Histoire Naturelle , Sorbonne Université, UMR CNRS 7590 , 61 rue Buffon , 75005 Paris , France.
  • Aléon J; Institut d'Astrophysique Spatiale (IAS) , Université Paris-Saclay , 91405 Orsay , France.
  • Aléon-Toppani A; Institut de Minéralogie de Physique des Matériaux, de Minéralogie et de Cosmochimie (IMPMC), Museum National d'Histoire Naturelle , Sorbonne Université, UMR CNRS 7590 , 61 rue Buffon , 75005 Paris , France.
  • Troadec D; Institut d'Astrophysique Spatiale (IAS) , Université Paris-Saclay , 91405 Orsay , France.
  • Duhamel R; Institut d'Electronique Microélectronique et Nanotechnologie (IEMN), CNRS , Université de Lille , Avenue Poincaré , 59652 Villeneuve-d'Ascq , France.
  • Gonzalez-Cano A; Institut de Minéralogie de Physique des Matériaux, de Minéralogie et de Cosmochimie (IMPMC), Museum National d'Histoire Naturelle , Sorbonne Université, UMR CNRS 7590 , 61 rue Buffon , 75005 Paris , France.
  • Bureau H; Institut de Minéralogie de Physique des Matériaux, de Minéralogie et de Cosmochimie (IMPMC), Museum National d'Histoire Naturelle , Sorbonne Université, UMR CNRS 7590 , 61 rue Buffon , 75005 Paris , France.
  • Khodja H; Institut de Minéralogie de Physique des Matériaux, de Minéralogie et de Cosmochimie (IMPMC), Museum National d'Histoire Naturelle , Sorbonne Université, UMR CNRS 7590 , 61 rue Buffon , 75005 Paris , France.
Anal Chem ; 91(21): 13763-13771, 2019 11 05.
Article em En | MEDLINE | ID: mdl-31549804
ABSTRACT
The D/H ratio imaging of weakly hydrated minerals prepared as focused ion beam (FIB) sections is developed in order to combine isotopic imaging by nanoscale secondary ion mass spectrometry (NanoSIMS) of micrometer-sized grains with other nanoscale imaging techniques, such as transmission electron microscopy. In order to maximize the accuracy, sensitivity, precision, and reproducibility of D/H ratios at the micrometer size, while minimizing the surface contamination at the same time, we explored all instrumental parameters known to influence the measurement of D/H ratios in situ. Optimal conditions were found to be obtained with the use of (i) a Cs+ ion source and detection of H- and D- at low mass resolving power, (ii) a primary beam intensity of 100 pA, and (iii) raster sizes in the range of 8-15 µm. Nominally anhydrous minerals were used to evaluate the detection limits and indicate a surface contamination level of ∼200 ppm equivalent H2O under these conditions. With the high primary intensity used here, the dwell time is not a parameter as critical as found in previous studies and a dwell time of 1 ms/px is used to minimize dynamic contamination during analysis. Analysis of FIB sections was found to reduce significantly static contamination due to sample preparation and improved accuracy compared to using polished sections embedded not only in epoxy but in indium as well. On amphiboles, the typical overall uncertainty including reproducibility is ∼20 ‰ on bulk FIB sections and ∼50 ‰ at the 1.5 µm scale using image processing (1σ).

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article