Your browser doesn't support javascript.
loading
Activate capture and digital counting (AC + DC) assay for protein biomarker detection integrated with a self-powered microfluidic cartridge.
Che, Congnyu; Li, Nantao; Long, Kenneth D; Aguirre, Miguel Ángel; Canady, Taylor D; Huang, Qinglan; Demirci, Utkan; Cunningham, Brian T.
Afiliação
  • Che C; Department of Bioengineering, University of Illinois at Urbana-Champaign, 208 North Wright Street, Urbana, IL 61801, USA. bcumming@illinois.edu.
  • Li N; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 208 North Wright Street, Urbana, IL 61801, USA.
  • Long KD; Department of Bioengineering, University of Illinois at Urbana-Champaign, 208 North Wright Street, Urbana, IL 61801, USA. bcumming@illinois.edu.
  • Aguirre MÁ; Department of Analytical Chemistry and Food Science and University Institute of Materials, Faculty of Science, University of Alicante, P.O. Box 99, 03080 Alicante, Spain.
  • Canady TD; Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 West Gregory Drive, Urbana, IL 61801, USA.
  • Huang Q; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 208 North Wright Street, Urbana, IL 61801, USA.
  • Demirci U; Bio-Acoustic MEMS in Medicine (BAMM) Laboratory, Canary Center at Stanford for Cancer Early Detection, Department of Radiology School of Medicine Stanford University, Palo Alto, CA 94304, USA.
  • Cunningham BT; Department of Bioengineering, University of Illinois at Urbana-Champaign, 208 North Wright Street, Urbana, IL 61801, USA. bcumming@illinois.edu and Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 208 North Wright Street, Urbana, IL 61801, USA and Carl R
Lab Chip ; 19(23): 3943-3953, 2019 12 07.
Article em En | MEDLINE | ID: mdl-31641717
ABSTRACT
We demonstrate a rapid, 2-step, and ultrasensitive assay approach for quantification of target protein molecules from a single droplet test sample. The assay is comprised of antibody-conjugated gold nanoparticles (AuNPs) that are "activated" when they are mixed with the test sample and bind their targets. The resulting liquid is passed through a microfluidic channel with a photonic crystal (PC) biosensor that is functionalized with secondary antibodies to the target biomarker, so that only activated AuNPs are captured. Utilizing recently demonstrated hybrid optical coupling between the plasmon resonance of the AuNP and the resonance of the PC, each captured AuNP efficiently quenches the resonant reflection of the PC, thus enabling the captured AuNPs to be digitally counted with high signal-to-noise. To achieve a 2-step assay process that is performed on a single droplet test sample without washing steps or active pump elements, controlled single-pass flow rate is obtained with an absorbing paper pad waste reservoir embedded in a microfluidic cartridge. We use the activate capture and digital counting (AC + DC) approach to demonstrate HIV-1 capsid antigen p24 detection from a 40 µL spiked-in human serum sample at a one thousand-fold dynamic range (1-103 pg mL-1) with only a 35-minute process that is compatible with point-of-care (POC) analysis. The AC + DC approach allows for ultrasensitive and ultrafast biomolecule detection, with potential applications in infectious disease diagnostics and early stage disease monitoring.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína do Núcleo p24 do HIV / Técnicas Analíticas Microfluídicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Lab Chip Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína do Núcleo p24 do HIV / Técnicas Analíticas Microfluídicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Lab Chip Ano de publicação: 2019 Tipo de documento: Article