Your browser doesn't support javascript.
loading
Comparisons of Manual Tape Measurement and Morphomics Measurement of Patients with Upper Extremity Lymphedema.
Horbal, Steven R; Chu, Sung-Yu; Wang, Nicholas C; Chan, Wen-Hui; Huang, Yen-Ling; Brown, Edward; Holcombe, Sven A; Cederna, Paul S; Wang, Stewart C; Cheng, Ming-Huei.
Afiliação
  • Horbal SR; Morphomic Analysis Group, University of Michigan, Ann Arbor, Mich.
  • Chu SY; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Institute for Radiological Research, Chang Gung University, Taoyuan City, Taiwan.
  • Wang NC; Morphomic Analysis Group, University of Michigan, Ann Arbor, Mich.
  • Chan WH; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Institute for Radiological Research, Chang Gung University, Taoyuan City, Taiwan.
  • Huang YL; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Institute for Radiological Research, Chang Gung University, Taoyuan City, Taiwan.
  • Brown E; Morphomic Analysis Group, University of Michigan, Ann Arbor, Mich.
  • Holcombe SA; Morphomic Analysis Group, University of Michigan, Ann Arbor, Mich.
  • Cederna PS; Department of Surgery, University of Michigan, Ann Arbor, Mich.
  • Wang SC; Section of Plastic Surgery, Department of Surgery, University of Michigan, Ann Arbor, Mich.
  • Cheng MH; Morphomic Analysis Group, University of Michigan, Ann Arbor, Mich.
Plast Reconstr Surg Glob Open ; 7(10): e2431, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31772880
ABSTRACT

BACKGROUND:

Lymphedema is a debilitating condition characterized by swelling from lymph fluid exceeding transport capacity. A gold standard for arm measurement is not established, and measurement methods vary. This study evaluates the comparability of the tape measure and Analytic Morphomics in deriving limb circumference measurements in patients with upper extremity lymphedema.

METHODS:

Fifteen participants with diagnosed upper limb lymphedema were included between July 2013 and June 2017 at Chang Gung Memorial Hospital in Taipei, Taiwan. Affected and unaffected arm circumferences were measured using a flexible tape or morphomic measurement at 10 cm above and below the elbow. Computed tomography scans were standardized, processed, smoothed with a piecewise polynomial algorithm for Analytic Morphomics of arm circumference. Comparative plots, mean percent difference, and adjusted coefficient of determination (R 2) were utilized to compare the consistency of both measurement procedures.

RESULTS:

The tape measure and Analytic Morphomics demonstrated consistent measures of arm circumference. On the affected arm, the mean (95% CI) difference in arm circumference between methods was 1.60 cm (0.99-2.20) above, and 0.57 cm (0.23-0.91) below the elbow. Mean percent differences in circumference was 6.65% (SD 3.52%) above and 1.38% (SD 2.11%) below the elbow. The adjusted R 2 for both methods was 94% above and 96% below the elbow.

CONCLUSIONS:

Analytic Morphomics showed strong consistency with the manual tape measure of arm circumference measurement in those with upper extremity lymphedema. Analytic Morphomics present an opportunity for a precise, granular measurement of limb composition for assessment of disease state and patient planning.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Plast Reconstr Surg Glob Open Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Plast Reconstr Surg Glob Open Ano de publicação: 2019 Tipo de documento: Article