Your browser doesn't support javascript.
loading
Real-Time Detection of Aerosol Metals Using Online Extractive Electrospray Ionization Mass Spectrometry.
Giannoukos, Stamatios; Lee, Chuan Ping; Tarik, Mohamed; Ludwig, Christian; Biollaz, Serge; Lamkaddam, Houssni; Baltensperger, Urs; Henry Prevot, Andre Stephan; Slowik, Jay.
Afiliação
  • Ludwig C; Engineering (ENAC) , École Polytechnique Fédérale de Lausanne (EPFL) , CH 1015 Lausanne , Switzerland.
Anal Chem ; 92(1): 1316-1325, 2020 01 07.
Article em En | MEDLINE | ID: mdl-31825206
ABSTRACT
Metal emissions are of major environmental and practical concern because of their highly toxic effects on human health and ecosystems. Current technologies available in the market for their detection are typically limited by a time resolution of 1 h or longer (e.g., via semicontinuous X-ray fluorescence measurements) or are nonquantitative (e.g., laser ablation mass spectrometry). In this work, we report the development of a novel technique for the real-time detection and monitoring of metal particles in situ using an extractive electrospray ionization (EESI) source coupled to a high-resolution time-of-flight mass spectrometer (TOF-MS). The experiments were conducted in negative ionization mode using disodium ethylenediamine tetraacetic acid (EDTA) dihydrate to chelate with metals and form stable metal complexes. Results for water-soluble metal compounds were obtained. The following representative metal ions were examined Pb, Cd, Zn, Ce (III), Ba, Ni, Fe(II), Fe(III), Cu(II), Cr, Mo, Co(II), Mg, Nd, Li, Ti, Ca, Cs, Ag, Tm, Er(III), La(III), Yb(III), Eu(III), Pr(III), Gd(III), Lu(III), Dy(III), Tb(III), Ho, and Ru(III). The results showed a very good linear mass response (R2 = 0.9983), low ng/m3 limits of detection (LoD), and a fast response time (1 s). The stability and repeatability of the developed EESI-TOF-MS were tested under complex dynamic and periodic experimental conditions, and negligible matrix effects were measured for internally and externally mixed metal particles. Benchmark testing against inductively coupled plasma-mass spectrometry (ICP-MS) was also performed, highlighting the online measurement capabilities of aerosol metals with a LoD lower than those of ICP-MS. Proof-of-concept ambient measurements were performed in New Delhi, India, and very promising results were obtained, allowing further exploitation elsewhere.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Metais Pesados Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Metais Pesados Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2020 Tipo de documento: Article