Your browser doesn't support javascript.
loading
Switchable fluorescence sensor toward PAT via CA-MWCNTs quenched aptamer-tagged carboxyfluorescein.
Khan, Reem; Sherazi, Tauqir A; Catanante, Gaelle; Rasheed, Sidra; Marty, Jean Louis; Hayat, Akhtar.
Afiliação
  • Khan R; BAE: Biocapteurs-Analyses-Environnement, Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan CEDEX, France; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, 22060, Pakistan. Electronic address: rekhan@clarkson.edu.
  • Sherazi TA; Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, 22060, Pakistan. Electronic address: sherazi@cuiatd.edu.pk.
  • Catanante G; BAE: Biocapteurs-Analyses-Environnement, Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan CEDEX, France. Electronic address: gaelle.catanante@univ-perp.fr.
  • Rasheed S; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus, 54000, Pakistan. Electronic address: srasheed075@gmail.com.
  • Marty JL; BAE: Biocapteurs-Analyses-Environnement, Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan CEDEX, France; Sensbiotech, 21rue de Nogarede, 66400 Ceret, France. Electronic address: jlmarty@univ-perp.fr.
  • Hayat A; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus, 54000, Pakistan. Electronic address: akhtarhayat@cuilahore.edu.pk.
Food Chem ; 312: 126048, 2020 May 15.
Article em En | MEDLINE | ID: mdl-31918363
ABSTRACT
A quenching based apta-sensing platform was developed for the detection of Patulin. Three different aptamer sequences were studied to screen the aptamer with the maximum affinity towards Patulin. Carboxyfluorescein (CFL) was used as a fluorescent dye while -COOH functionalized multiwall carbon nanotubes (MWCNTs) were applied as novel nanoquenchers. Aptamer tagged at the 3' end with 40 nucleotide bases exhibited the maximum affinity towards Patulin and caused substantial fluorescence recovery. Interestingly, the limit of detection (LOD) and limit of quantification (LOQ) were calculated as 0.13 µg L-1and 0.41 µg L-1 respectively. Commonly occurring mycotoxins in food were also tested to confirm the selectivity of apta-assay. The developed apta-assay was applied to a spiked apple juice sample and toxin recoveries were observed ranging from 96% to 98% (n = 3). These results demonstrated the potential of the developed apta-assay for the selective detection and quantification of Patulin in food samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Fluoresceínas Idioma: En Revista: Food Chem Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Fluoresceínas Idioma: En Revista: Food Chem Ano de publicação: 2020 Tipo de documento: Article