Your browser doesn't support javascript.
loading
Shear-Wave Elastography Variability Analysis and Relation with Kidney Allograft Dysfunction: A Single-Center Study.
Bolboaca, Sorana D; Elec, Florin Ioan; Elec, Alina Daciana; Muntean, Adriana Milena; Socaciu, Mihai Adrian; Iacob, Gheorghita; Zaro, Razvan; Andrieș, Alexandra-Ioana; Badulescu, Ramona Maria; Ignat, Radu Mihai; Iancu, Mihaela; Badea, Radu Ion.
Afiliação
  • Bolboaca SD; Department of Medical Informatics and Biostatistics, Iuliu Hațieganu University of Medicine and Pharmacy Cluj-Napoca, Louis Pasteur Str., no. 6, 400349 Cluj-Napoca, Romania.
  • Elec FI; Department of Urology, Iuliu Hațieganu University of Medicine and Pharmacy Cluj-Napoca, Clinicilor Str., no. 4-6, 400006 Cluj-Napoca, Romania.
  • Elec AD; Department of Renal Transplantation, Clinical Institute of Urology and Renal Transplantation, Clinicilor Str., no. 4-6, 400006 Cluj-Napoca, Romania.
  • Muntean AM; Department of Renal Transplantation, Clinical Institute of Urology and Renal Transplantation, Clinicilor Str., no. 4-6, 400006 Cluj-Napoca, Romania.
  • Socaciu MA; Department of Renal Transplantation, Clinical Institute of Urology and Renal Transplantation, Clinicilor Str., no. 4-6, 400006 Cluj-Napoca, Romania.
  • Iacob G; Department of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy Cluj-Napoca, Croitorilor Str., no. 19-23, 400162 Cluj-Napoca, Romania.
  • Zaro R; Department of Medical Imaging, "Prof. Dr. Octavian Fodor" Regional Institute of Gastroenterology and Hepatology, Constanța Str., no. 5, 400162 Cluj-Napoca, Romania.
  • Andrieș AI; Department of Renal Transplantation, Clinical Institute of Urology and Renal Transplantation, Clinicilor Str., no. 4-6, 400006 Cluj-Napoca, Romania.
  • Badulescu RM; Department of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy Cluj-Napoca, Croitorilor Str., no. 19-23, 400162 Cluj-Napoca, Romania.
  • Ignat RM; Department of Medical Imaging, "Prof. Dr. Octavian Fodor" Regional Institute of Gastroenterology and Hepatology, Constanța Str., no. 5, 400162 Cluj-Napoca, Romania.
  • Iancu M; Department of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy Cluj-Napoca, Croitorilor Str., no. 19-23, 400162 Cluj-Napoca, Romania.
  • Badea RI; Department of Medical Imaging, "Prof. Dr. Octavian Fodor" Regional Institute of Gastroenterology and Hepatology, Constanța Str., no. 5, 400162 Cluj-Napoca, Romania.
Diagnostics (Basel) ; 10(1)2020 Jan 13.
Article em En | MEDLINE | ID: mdl-31941112
ABSTRACT
Shear-wave elastography (SWE) showed the absence or presence of significant differences among stable kidney allograft function and allograft dysfunction. We evaluated the variability of kidney allograft stiffness in relation to allograft dysfunction, respectively, in terms of a correlation of stiffness with patients' characteristics. A single-center prospective study on patients who had undergone renal transplantation was conducted between October 2017 and November 2018. Patients were clinically classified as having a stable allograft function or allograft dysfunction. SWE examinations performed by the same radiologist with a LOGIQ E9 were evaluated. Ten measurements were done for Young's modulus (kPa) at the level of allograft cortex and another ten at the level of medulla. Eighty-three SWE examinations from 63 patients, 69 stable allografts, and 14 allografts with dysfunction were included in the analysis. The intra-examinations stiffness showed high variability, with the quantile covariation coefficient ranging from 2.21% to 45.04%. The inter-examinations stiffness showed heterogeneity (from 28.66% to 42.38%). The kidney allograft cortex stiffness showed significantly higher values in cases with dysfunction (median = 28.70 kPa, interquartile range (IQR) = (25.68-31.98) kPa) as compared to those with stable function (median = 20.99 kPa, interquartile range = (16.08-27.68) kPa; p-value = 0.0142). Allograft tissue stiffness (both cortex and medulla) was significantly negatively correlated with body mass index (-0.44, p-value < 0.0001 for allograft cortex and -0.42, p-value = 0.0001 for allograft medulla), and positively correlated with Proteinuria/Creatinuria ratio (0.33, p-value = 0.0021 for allograft cortex and 0.28, p-value = 0.0105 for allograft medulla) but remained statistically significant only in cases with stable function. The cortical tissue stiffness proved significantly higher values for patients with allograft dysfunction as compared to patients with stable function, but to evolve as an additional tool for the evaluation of patients with a kidney transplant and to change the clinical practice, more extensive studies are needed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2020 Tipo de documento: Article